modelTransformer
Transformer model
Information
Description
This transformer model considers the following effects:
- Winding resistances
- Leakage inductances
- Number of turns of windings
- Main reluctance of the core
- Eddy current core loss
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Integer | N1 | Number of primary turns | |
| Integer | N2 | Number of secondary turns | |
| Modelica.Units.SI.Resistance | R1 | Primary resistance | |
| Modelica.Units.SI.Resistance | R2 | Secondary resistance | |
| Modelica.Units.SI.Permeance | G_m1sigma | Primary stray inductance | |
| Modelica.Units.SI.Permeance | G_m2sigma | Secondary stray inductance | |
| Modelica.Units.SI.Reluctance | R_m | Main field reluctance | |
| Modelica.Units.SI.Conductance | Gc | Eddy current loss conductance |
Connectors
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Units.SI.Current | i1 | p1.i | Primary current |
| Modelica.Units.SI.Current | i2 | p2.i | Secondary current |
| Modelica.Units.SI.Voltage | v1 | p1.v - n1.v | Primary voltage |
| Modelica.Units.SI.Voltage | v2 | p2.v - n2.v | Secondary voltage |
| Modelica.Magnetic.FluxTubes.Basic.ElectroMagneticConverter | converter1 | ||
| Modelica.Magnetic.FluxTubes.Basic.ElectroMagneticConverter | converter2 | ||
| Modelica.Magnetic.FluxTubes.Basic.Ground | ground | ||
| Modelica.Electrical.Analog.Basic.Resistor | resistor2 | ||
| Modelica.Magnetic.FluxTubes.Basic.ConstantPermeance | strayPermeanc1 | ||
| Modelica.Electrical.Analog.Basic.Resistor | resistor1 | ||
| Modelica.Magnetic.FluxTubes.Basic.ConstantPermeance | strayPermeanc2 | ||
| Modelica.Magnetic.FluxTubes.Basic.EddyCurrent | eddyCurrent | ||
| Modelica.Magnetic.FluxTubes.Basic.ConstantReluctance | mainReluctance | ||
| Modelica.Magnetic.FluxTubes.Basic.Crossing | crossing |