modelSMEE_LoadDump
Electrical excited synchronous machine with voltage controller
Extends from Modelica.Icons.Example (Icon for runnable examples).
Information
Description
An electrically excited synchronous generator is started with a speed ramp, then driven with constant speed. Voltage is controlled, the set point depends on speed. After start-up the generator is loaded, the load is rejected.
Plot the following variable(s)
smee.wMechanical: speedvoltageRMSSensor.V: RMS stator voltagecurrentRMSSensor.I: RMS stator currentsmee.ve: excitation voltagesmee.ie: excitation current
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Integer | m | 3 | Number of phases |
| Modelica.Units.SI.AngularVelocity | wNominal | 2*pi*smeeData.fsNominal/smee.p | Nominal speed |
| Modelica.Units.SI.Impedance | ZNominal | 3*smeeData.VsNominal^2/smeeData.SNominal | Nominal load impedance |
| Real | powerFactor | 0.8 | Load power factor |
| Modelica.Units.SI.Resistance | RLoad | ZNominal*powerFactor | Load resistance |
| Modelica.Units.SI.Inductance | LLoad | ZNominal*sqrt(1 - powerFactor^2)/(2*pi*smeeData.fsNominal) | Load inductance |
| Modelica.Units.SI.Voltage | Ve0 | smee.IeOpenCircuit*Modelica.Electrical.Machines.Thermal.convertResistance(smee.Re, smee.TeRef, smee.alpha20e, smee.TeOperational) | No load excitation voltage |
| Real | k | 2*Ve0/smeeData.VsNominal | Voltage controller: gain |
| Modelica.Units.SI.Time | Ti | smeeData.Td0Transient/2 | Voltage controller: integral time constant |
| ParameterRecords.SMEE1 | smeeData | Synchronous machine data |