modelZoneStepResponse
Example to test the thermal step response of a SimpleZone
Extends from Modelica.Icons.Example.
Information
This example tests the step response of the SimpleZone model for the airflow benchmark. It uses
the weather file STEP_TMY.mos, that implements a 5 Kelvin step at t=400 000
seconds. In the Buildings library, the room model of BESTEST 600 FF needs around 4-5 hours in
order to reach 2/3 of the maximum step response to this weather file. This time constant is
approximated with a value of mSenFac = 75 for the mixing volume of the zone.
The mass flow rate of air to the zone is 0.05 kg/s, which approximates an air exchange rate of 3 times the air volume per hour.
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.SIunits.Temperature | TRoom | simpleZone.volRoom.heatPort.T | Room temperature at volume's therm port |
| Components.SimpleZone | simpleZone | Simple zone element for step response test | |
| Fluid.Sources.MassFlowSource_T | boundary | Mass flow source for air exchange in the zone | |
| Fluid.Sources.FixedBoundary | bou | Boundary condition for air exchange in the zone | |
| BoundaryConditions.WeatherData.ReaderTMY3 | weaDat | Weather data reader for input data | |
| BoundaryConditions.WeatherData.Bus | weaBus | Weather bus for temperature input | |
| Modelica.Blocks.Sources.Step | step |
Contents
| Name | Description |
|---|---|
| Medium | Medium in the component |
Revisions
-
May 28, 2015, by Marcus Fuchs:
First implementation.