modelPartialPrescribedOutlet
Ideal heater, cooler, humidifier or dehumidifier with prescribed outlet conditions
Extends from IBPSA.Fluid.Interfaces.PartialTwoPortInterface, IBPSA.Fluid.Interfaces.TwoPortFlowResistanceParameters.
Information
Base class for model for an ideal heater, cooler, humidifier or dehumidifier with a prescribed outlet conditions.
Models that extend this model need to configure the instance outCon
and connect its input signals, in they are enabled.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Nominal condition | |||
| Modelica.SIunits.MassFlowRate | m_flow_nominal | Nominal mass flow rate, used for regularization near zero flow | |
| Dynamics | |||
| Modelica.SIunits.Time | tau | 10 | Time constant at nominal flow rate (used if energyDynamics or massDynamics not equal Modelica.Fluid.Types.Dynamics.SteadyState) |
| Advanced | |||
| Boolean | homotopyInitialization | true | = true, use homotopy method |
Revisions
-
May 3, 2017, by Michael Wetter:
Updated protected model for #763. -
December 1, 2016, by Michael Wetter:
Updated model asuse_dhis no longer a parameter in the pressure drop model.
This is for #480. -
November 11, 2014, by Michael Wetter:
Revised implementation. -
March 19, 2014, by Christoph Nytsch-Geusen:
First implementation.