modelStrobeInfoManager
StROBe information manager for handling occupant data required in each for simulation.
Information
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| String | filDir | Modelica.Utilities.Files.loadResource("modelica://IDEAS") + "/Inputs/" | Directory containing the data files, default under IDEAS/Inputs/ |
| Integer | nOcc | 33 | Number of occupant profiles to be read |
| Modelica.Units.SI.Time | startTime | 0 | Output = offset for time < startTime |
| StROBe power load | |||
| Boolean | StROBe_P | true | Boolean to read plug load profiles |
| String | FilNam_P | "none.txt" | File with (active) plug load profiles from StROBe (in W) |
| StROBe | |||
| Boolean | StROBe | true | Boolean to read the other profiles too |
| String | FilNam_Q | "none.txt" | File with (reactive) plug load profiles (in W) |
| String | FilNam_mDHW | "none.txt" | File with hot watter tapping profiles (in l/min) |
| String | FilNam_QCon | "none.txt" | File with (convective) internal heat gain profiles (in W) |
| String | FilNam_QRad | "none.txt" | File with (radiative) internal heat gain profiles (in W) |
| String | FilNam_TSet | "none.txt" | File with (main) space heating setpoint profiles (in K) |
| String | FilNam_TSet2 | "none.txt" | File with (secondary) space heating setpoint profiles (in K) |
| Heat pumps | |||
| Boolean | PHp | false | Boolean to read heat pump load profiles |
| String | FilNam_PHp | "none.txt" | File with (active) electric load heat pump profiles (in W) |
| Photovoltaics | |||
| Boolean | PPv | false | Boolean to read photovoltaic load profiles |
| String | FilNam_PPv | "none.txt" | File with (active) photovoltaic load profiles (in W) |
| Integer | nPv | 33 | Number of photovoltaic profiles |
| Modelica.Units.SI.Power | P_nominal | 1000 | Nominal power of the photovoltaic profiles |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Blocks.Sources.CombiTimeTable | tabQCon | ||
| Modelica.Blocks.Sources.CombiTimeTable | tabQRad | ||
| Modelica.Blocks.Sources.CombiTimeTable | tabTSet | ||
| Modelica.Blocks.Sources.CombiTimeTable | tabP | ||
| Modelica.Blocks.Sources.CombiTimeTable | tabQ | ||
| Modelica.Blocks.Sources.CombiTimeTable | tabDHW | ||
| Modelica.Blocks.Sources.CombiTimeTable | tabPPv | ||
| Modelica.Blocks.Sources.CombiTimeTable | tabTSet2 | ||
| Modelica.Blocks.Sources.CombiTimeTable | tabPHp | ||
| Modelica.Blocks.Interfaces.RealOutput | tabQCon_internal | Needed to connect to conditional connector | |
| Modelica.Blocks.Interfaces.RealOutput | tabQRad_internal | Needed to connect to conditional connector | |
| Modelica.Blocks.Interfaces.RealOutput | tabTSet_internal | Needed to connect to conditional connector | |
| Modelica.Blocks.Interfaces.RealOutput | tabP_internal | Needed to connect to conditional connector | |
| Modelica.Blocks.Interfaces.RealOutput | tabQ_internal | Needed to connect to conditional connector | |
| Modelica.Blocks.Interfaces.RealOutput | tabDHW_internal | Needed to connect to conditional connector | |
| Modelica.Blocks.Interfaces.RealOutput | tabPPv_internal | Needed to connect to conditional connector | |
| Modelica.Blocks.Interfaces.RealOutput | tabTSet2_internal | Needed to connect to conditional connector | |
| Modelica.Blocks.Interfaces.RealOutput | tabPHp_internal | Needed to connect to conditional connector |
Revisions
-
April 1, 2020 by Jelger Jansen:
Added conditional connectors to be in line with the Modelica specification. See #1125. -
December 20, 2017 by Bram van der Heijde:
Propagate start time ofCombiTimeTables inStrobeInfoManagerand make data reader repeat input data to avoid errors.