modelPartialOccupancyGains
Partial model for occupant internal gains
Extends from Modelica.Blocks.Icons.Block.
Parameters
| Type | Name | Default | Description |
| IDEAS.Buildings.Components.OccupancyType.OfficeWork | occupancyType | | |
| Real[max(Medium.nC, 1)] | s_co2 | {if Modelica.Utilities.Strings.isEqual(string1 = if Medium.nC > 0 then Medium.extraPropertiesNames[i] else "", string2 = "CO2", caseSensitive = false) then 1 else 0 for i in 1:max(Medium.nC, 1)} | Array with 1 on the position where CO2 is situated in the Medium.extraPropertiesNames |
| Modelica.Units.SI.SpecificEnthalpy | lambdaWater | if (Medium.nX) > 1 then Medium.enthalpyOfCondensingGas(T = 273.15 + 35) else 2566120 | Latent heat of evaporation of water at 35 degrees Celsius |
Components
| Type | Name | Default | Description |
| IDEAS.BoundaryConditions.SimInfoManager | sim | | Simulation information manager |
| Modelica.Blocks.Interfaces.RealOutput | mWat_flow | | Water vapor mass flow rate due to occupants |
| Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a | portCon | | Port for convective sensible heat transfer due to occupants |
| Modelica.Blocks.Interfaces.RealOutput[max(Medium.nC, 1)] | C_flow | | Trace substance mass flow rate due to occupants |
| Modelica.Blocks.Interfaces.RealInput | nOcc | | Number of occupants |
| Modelica.Thermal.HeatTransfer.Sources.PrescribedHeatFlow | preHeaFlo | | Prescribed energy heat flow for conservation of energy check |
| Modelica.Blocks.Sources.RealExpression | Qgai | | |
| Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a | portRad | | Port for radiative sensible heat transfer due to occupants |
Contents
| Name | Description |
| Medium | Medium in the component |
Revisions
-
July 26, 2018 by Filip Jorissen:
Revised implementation to add support for
#760.
-
July 18, 2016 by Filip Jorissen:
First implementation