recordCN_Jonas2018
A record of IDEAS.Fluid.PVTCollectors.Data.Generic.
Information
This record contains thermal and electrical parameters for a covered PVT collector without rear insulation,
based on experimental identification results from Jonas et al. (2018).
These parameters were used in the validation of a TRNSYS PVT collector model under ISO 9806:2013 and converted
to the ISO 9806:2017 quasi‑dynamic formulation used by
IDEAS.Fluid.PVTCollectors.PVTCollector using the Excel
file located in IDEAS/Resources/Data/Fluid/PVTCollectors.
This record can be used as a generic representation of a covered, non-insulated PVT collector. However, if you know the brand and model of the PVT collector you plan to simulate or install, it is recommended to use the actual datasheet parameters in a custom IDEAS.Fluid.PVTCollectors.Data.GenericQuasiDynamic record.
References
- Jonas, D., Theis, D., Frey, G. (2018). Implementation and Experimental Validation of a Photovoltaic-Thermal (PVT) Collector Model in TRNSYS. EuroSun 2018. DOI: 10.18086/eurosun2018.02.16
Attributes
| Name | Value |
|---|---|
| A final | 1.79 |
| CTyp final | IDEAS.Fluid.SolarCollectors.Types.HeatCapacity.TotalCapacity |
| C final | 16075*1.79 |
| V final | 5/1000 |
| mDry final | 24 |
| mperA_flow_nominal final | 0.03 |
| dp_nominal final | 60000 |
| incAngDat final | Modelica.Units.Conversions.from_deg({0, 10, 20, 30, 40, 50, 60, 70, 90}) |
| incAngModDat final | {1, 1, 0.99, 0.98, 0.97, 0.95, 0.92, 0.88, 0.00} |
| colTyp final | IDEAS.Fluid.PVTCollectors.Types.CollectorType.Covered |
| IAMDiff final | (0.596*0.93 - 3*0.009)/(0.596 - 3*0.009) |
| eta0 final | 0.596 - 3*0.009 |
| a1 final | 6.583 + 3*0.000 |
| a2 final | 0.021 |
| a3 final | 0.000 |
| a4 final | 0.066 |
| a6 final | 0.009 |
| a7 final | 0.0 |
| a8 final | 0.0 |
| P_nominal final | 280 |
| beta final | -0.00370 |
| etaEl final | 0.1406 |