recordUI_Validation
A record of IDEAS.Fluid.PVTCollectors.Data.Generic.
Information
This record contains anonymized thermal and electrical performance parameters for
an uncovered photovoltaic–thermal (PVT) collector with rear insulation.
The collector was originally tested under ISO 9806:2013 conditions and subsequently
converted to the ISO 9806:2017 quasi‑dynamic formulation used by
IDEAS.Fluid.PVTCollectors.PVTCollector, using the Excel conversion file located at
IDEAS.Resources.Data.Fluid.PVTCollectors.
Thermal performance parameters correspond to operation of the collector in maximum
power point (MPP) mode.
This datasheet is used in the validation of IDEAS.Fluid.PVTCollectors.PVTQuasiDynamicCollector, which can be found in the IDEAS.Fluid.PVTCollectors.Validation.PVT_UI package.
References
Attributes
| Name | Value |
|---|---|
| A final | 1.66 |
| CTyp final | IDEAS.Fluid.SolarCollectors.Types.HeatCapacity.TotalCapacity |
| C final | 42200*1.66 |
| V final | 5/1000 |
| mDry final | 28 |
| mperA_flow_nominal final | 0.03 |
| dp_nominal final | 60000 |
| incAngDat final | Modelica.Units.Conversions.from_deg({0, 10, 20, 30, 40, 50, 60, 70, 90}) |
| incAngModDat final | {1, 1, 1, 0.99, 0.99, 0.98, 0.96, 0.92, 0.00} |
| colTyp final | IDEAS.Fluid.PVTCollectors.Types.CollectorType.Uncovered |
| IAMDiff final | (0.475*1 - 3*0.003)/(0.475 - 3*0.003) |
| eta0 final | 0.475 - 3*0.003 |
| a1 final | 7.411 + 3*1.7 |
| a2 final | 0.0 |
| a3 final | 1.7 |
| a4 final | 0.437 |
| a6 final | 0.003 |
| a7 final | 0.0 |
| a8 final | 0.0 |
| P_nominal final | 280 |
| beta final | -0.0041 |
| etaEl final | 0.1687 |