recordUN_Jonas2018
A record of IDEAS.Fluid.PVTCollectors.Data.Generic.
Information
This record contains thermal and electrical parameters for an uncovered and non-insulated PVT collector (WISC type),
based on experimental identification results from Jonas et al. (2018).
These parameters were used in the validation of a TRNSYS PVT collector model under ISO 9806:2013 and converted
to the ISO 9806:2017 quasi‑dynamic formulation used by
IDEAS.Fluid.PVTCollectors.PVTCollector using the Excel
file located at IDEAS.Resources.Data.Fluid.PVTCollectors.
This record can be used as a generic representation of a WISC-type collector. However, if you know the brand and model of the PVT collector you plan to simulate or install, it is recommended to use the actual datasheet parameters in a custom IDEAS.Fluid.PVTCollectors.Data.GenericQuasiDynamic record.
Reference
- Jonas, D., Theis, D., Frey, G. (2018). Implementation and Experimental Validation of a Photovoltaic-Thermal (PVT) Collector Model in TRNSYS. EuroSun 2018. DOI: 10.18086/eurosun2018.02.16
Attributes
| Name | Value |
|---|---|
| A final | 1.66 |
| CTyp final | IDEAS.Fluid.SolarCollectors.Types.HeatCapacity.TotalCapacity |
| C final | 35800*1.66 |
| V final | 5/1000 |
| mDry final | 20 |
| mperA_flow_nominal final | 0.03 |
| dp_nominal final | 60000 |
| incAngDat final | Modelica.Units.Conversions.from_deg({0, 10, 20, 30, 40, 50, 60, 70, 90}) |
| incAngModDat final | {1, 1, 0.99, 0.98, 0.97, 0.95, 0.92, 0.88, 0.00} |
| colTyp final | IDEAS.Fluid.PVTCollectors.Types.CollectorType.Uncovered |
| IAMDiff final | (0.436*0.91 - 3*0.008)/(0.436 - 3*0.008) |
| eta0 final | 0.436 - 3*0.008 |
| a1 final | 7.750 + 3*1.640 |
| a2 final | 0.026 |
| a3 final | 1.640 |
| a4 final | 0.000 |
| a6 final | 0.008 |
| a7 final | 0.0 |
| a8 final | 0.0 |
| P_nominal final | 280 |
| beta final | -0.00467 |
| etaEl final | 0.1688 |