modelISO9806HeatLossValidation
Validation variant with term‑by‑term breakdown of ISO9806:2017 standard thermal heat loss
Extends from IDEAS.Fluid.PVTCollectors.BaseClasses.ISO9806HeatLoss.
Information
Extends from the standard quasi‑dynamic heat‑loss model (IDEAS.Fluid.PVTCollectors.BaseClasses.ISO9806QuasiDynamicHeatLoss). For validation purposes, this block adds:
- A term‑by‑term breakdown of each thermal loss contribution;
- Cumulative sums showing how each additional term builds up to the total heat loss.
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Units.SI.Power | a1_a2_term | Contribution from a1_a2 term | |
| Modelica.Units.SI.Power | a3_term | Contribution from wind-speed dependence (a3) | |
| Modelica.Units.SI.Power | a4_term | Contribution from sky long-wave (a4) | |
| Modelica.Units.SI.Power | a6_term | Contribution from wind–irradiance coupling (a6) | |
| Modelica.Units.SI.Power | a7_term | Contribution from wind–irradiance dependence of IR radiation exchange (a7) | |
| Modelica.Units.SI.Power | a8_term | Contribution from radiation losses (a8) | |
| Modelica.Units.SI.Irradiance | EL_term | Sky long-wave irradiance difference (HHorIR – σ·TEnv⁴) | |
| Modelica.Units.SI.Power | pvt_st_st | a1_a2 | |
| Modelica.Units.SI.Power | pvt_a3 | a1_a2 + a3 | |
| Modelica.Units.SI.Power | pvt_a4 | a1_a2 + a3 + a4 | |
| Modelica.Units.SI.Power | pvt_a6 | a1_a2 + a3 + a4 + a6 | |
| Modelica.Units.SI.Power | pvt_a7 | a1_a2 + a3 + a4 + a6 + a7 | |
| Modelica.Units.SI.Power | pvt_a8 | a1_a2 + a3 + a4 + a6 + a7 + a8 |