recordUN_Validation

Parameters for an uncovered flat-plate PVT collector without rear cover or back-side insulation

A record of IDEAS.Fluid.PVTCollectors.Data.Generic.

Information

For comparison with the simplified steady-state thermal formulation, this validation record is adapted to use the thermal coefficients a1 and a2 reported under the EU Ecodesign Regulation CDR 812/2013, which are provided directly in the collector datasheet.

For this PVT collector, additional real-life measurement data is publicly available (Veynandt, 2023) and has been used in the validation of IDEAS.Fluid.PVTCollectors.PVTQuasiDynamicCollector, which can be found in the IDEAS.Fluid.PVTCollectors.Validation.PVT_UN package.

Certificate

References

Attributes

NameValue
A final1.64
CTyp finalIDEAS.Fluid.SolarCollectors.Types.HeatCapacity.TotalCapacity
C final22100*1.64
V final1.54/1000
mDry final30
mperA_flow_nominal final0.02
dp_nominal final300000
incAngDat finalModelica.Units.Conversions.from_deg({0, 10, 20, 30, 40, 50, 60, 70, 80, 90})
incAngModDat final{1, 1, 1, 1, 0.99, 0.97, 0.92, 0.80, 0.55, 0.00}
colTyp finalIDEAS.Fluid.PVTCollectors.Types.CollectorType.Uncovered
IAMDiff final0.97
eta0 final0.499
a1 final11.84
a2 final0.0
a3 final0.0
a4 final0.0
a6 final0.0
a7 final0.0
a8 final0.0
P_nominal final300
beta final-0.00375
etaEl final0.183

Revisions

  • March 11, 2026, by Lone Meertens:
    Added new record for comparing the full ISO 9806:2017 PVT model with the simplified EU Ecodesign Regulation CDR 812/2013 datasheet parameters. This is for #1473.