modelPPMTwoPort

Ideal two port trace substances sensor outputting in parts per million

Extends from IDEAS.Fluid.Sensors.BaseClasses.PartialDynamicFlowSensor, Modelica.Icons.RoundSensor.

Information

This model outputs the trace substance of the passing fluid in parts per million. The sensor is ideal, i.e., it does not influence the fluid. If the parameter tau is non-zero, then its output is computed using a first order differential equation. Setting tau=0 is not recommend. See IDEAS.Fluid.Sensors.UsersGuide for an explanation.

Parameters

TypeNameDefaultDescription
StringsubstanceName"CO2"Name of trace substance
Modelica.Units.SI.MolarMassMMModelica.Media.IdealGases.Common.SingleGasesData.CO2.MMMolar mass of the trace substance
Initialization
RealC_start0Initial or guess value of output (= state)

Components

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealOutputppmTrace substance in port medium in ppm

Revisions

  • February 25, 2020, by Michael Wetter:
    Changed icon to display its operating state.
    This is for #1294.
  • January 12, 2016, by Filip Jorissen:
    First implementation. See issue #372