modelStratified
Model of a stratified tank for thermal energy storage
Extends from IDEAS.Fluid.Storage.BaseClasses.PartialStratified.
Information
This is a model of a stratified storage tank.
See the IDEAS.Fluid.Storage.UsersGuide for more information.
For a model with enhanced stratification, use IDEAS.Fluid.Storage.StratifiedEnhanced.
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Fluid.Interfaces.FluidPorts_a[nSeg] | fluPorVol | Fluid port that connects to the control volumes of the tank |
Revisions
-
March 7, 2022, by Michael Wetter:
Setfinal massDynamics=energyDynamics.
This is for #1542. -
June 7, 2018 by Filip Jorissen:
Copied model from Buildings and update the model accordingly. This is for #314. -
June 1, 2018, by Michael Wetter:
Refactored model to allow a fluid port in the tank that do not have the enhanced stratification model.
This is for issue 1182. -
July 29, 2017, by Michael Wetter:
Removed medium declaration, which is not needed and inconsistent with the declaration in the base class. This is for issue 544. -
March 28, 2015, by Filip Jorissen:
PropagatedallowFlowReversalandm_flow_smalland setmSenFac=1. -
January 26, 2015, by Michael Wetter:
RenamedhA_flowtoH_a_flow,hB_flowtoH_b_flowandhVol_flowtoH_vol_flowas they output enthalpy flow rate, and not specific enthalpy. Made various modelsprotected. -
January 25, 2015, by Michael Wetter:
Addedfinaltotau = 0inEnthalpyFlowRate. These sensors do not need dynamics as the enthalpy flow rate is used to compute a heat flow which is then added to the volume of the tank. Thus, if there were high frequency oscillations of small mass flow rates, then they have a small effect onH_flow, and they are not used in any control loop. Rather, the oscillations are further damped by the differential equation of the fluid volume. -
January 25, 2015, by Filip Jorissen:
Settau = 0inEnthalpyFlowRatesensors for increased simulation speed. -
August 29, 2014, by Michael Wetter:
Replaced the use ofMedium.lambda_constwithMedium.thermalConductivity(sta_default)aslambda_constis not declared for all media. This avoids a translation error if certain media are used. -
June 18, 2014, by Michael Wetter:
Changed the default value for the energy balance initialization to avoid a dependency on the globalsystemdeclaration. -
July 29, 2011, by Michael Wetter:
Removeduse_T_startandh_start. -
February 18, 2011, by Michael Wetter:
Changed default start values for temperature and pressure. -
October 25, 2009 by Michael Wetter:
Changed computation of heat transfer through top (and bottom) of tank. Now, the thermal resistance of the fluid is not taken into account, i.e., the top (and bottom) element is assumed to be mixed. -
October 23, 2009 by Michael Wetter:
Fixed bug in computing heat conduction of top and bottom segment. In the previous version, for computing the heat conduction between the top (or bottom) segment and the outside, the whole thickness of the water volume was used instead of only half the thickness. -
February 19, 2009 by Michael Wetter:
Changed declaration that constrains the medium. The earlier declaration caused the medium model to be not shown in the parameter window. -
October 31, 2008 by Michael Wetter:
Added heat conduction. -
October 23, 2008 by Michael Wetter:
First implementation.