modelBalancedTap

DHW consumption with profile reader. RealInput mDHW60C is not used.

Extends from IDEAS.Fluid.Taps.Interfaces.BalancedTap.

Information

Description

Model of a domestic hot water (DHW) system composed mainly of a thermostatic mixing valve and a table for reading the DHW flow rate.

This model is an extension of the Partial_DHW model, see there for the documentation.

Examples

An example of this model is given in IDEAS.Thermal.Components.Examples.StorageTank_DHW_HP.

Parameters

TypeNameDefaultDescription
Modelica.Units.SI.VolumeVDayAvgAverage daily water consumption
IntegerprofileType1Type of the DHW tap profile

Components

TypeNameDefaultDescription
Modelica.Blocks.Tables.CombiTable1Dstableratio between the actual DHW mass flow rate (per second) and its average daily mass flow rate (per day)
Modelica.Blocks.Math.ProductmDHW60C
Modelica.Blocks.Sources.RealExpressionrealExpression1
Modelica.Blocks.Sources.RealExpressionmFloDayAvgAverage daily hot water consumption, at 60 degC

Revisions

  • June 5, 2018 by Filip Jorissen:
    Cleaned up implementation for #821.