modelStructure

Partial model for building structure models

Parameters

TypeNameDefaultDescription
Modelica.Units.SI.TemperatureT_startMedium.T_defaultOperative zonal start temperatures
IntegernZonesNumber of conditioned thermal zones in the building
IntegernEmbNumber of embedded systems in the building
Modelica.Units.SI.AreaATrans100Transmission heat loss area of the residential unit
Modelica.Units.SI.AreaAZonesones(nZones)*100Conditioned floor area of the zones
Modelica.Units.SI.VolumeVZonesAZones.*3Conditioned volume of the zones based on external dimensions
Modelica.Units.SI.LengthCsum(VZones)/ATransBuilding compactness
Modelica.Units.SI.PowerQ_designzeros(nZones)Design heat loss of zones
BooleanuseFluPortrueSet to false to remove fluid ports

Components

TypeNameDefaultDescription
IDEAS.BoundaryConditions.SimInfoManagersimSimulation information manager for climate data
Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_aheatPortConInternal zone nodes for convective heat gains
Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_aheatPortRadInternal zones node for radiative heat gains
Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_bheatPortEmbConstruction nodes for heat gains by embedded layers
Modelica.Blocks.Interfaces.RealOutputTSensorSensor temperature of the zones
Modelica.Fluid.Interfaces.FluidPort_bport_b
Modelica.Fluid.Interfaces.FluidPort_aport_a

Contents

NameDescription
Medium

Revisions

  • May 23, 2022, by Filip Jorissen:
    Fixed missing each for #1273.
  • March 8, 2017, by Filip Jorissen:
    Added option for removing fluid ports.