modelCase680FF

Extends from IDEAS.ThermalZones.ISO13790.Validation.BESTEST.Cases6xx.Case600FF.

Information

This model is used for the test case 680FF of the BESTEST validation suite. Case 680FF is a light-weight building with increased exterior wall and roof insulation. The room temperature is free floating.

Revisions

  • March 10, 2025, by Michael Wetter:
    Added missing semi-colon.
    This is for IBPSA, #1987.
  • May 3, 2024, Alessandro Maccarini:
    First implementation.