modelGen1
100MVA/18kV generation unit for bus 1
Extends from OpenIPSL.Interfaces.Generator (Interface for a generator which provides the PwPin).
Information
Note that this 100MVA/18kV generation unit allows the user to perform a step disturbance of magnitude height at instant tstart in the voltage reference value for each Automatic Voltage Regulator.
Also note that boolean variable refdisturb needs to be set to true for disturbance to take place.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | vf0 | 1.755517086537914 | Initial field voltage value |
| Real | vref0 | 1.118023800520641 | Initial terminal voltage reference value |
| Power flow data | |||
| Types.ApparentPower | S_b (from pfComponent) | SysData.S_b | System base power |
| Types.Voltage | V_b (from pfComponent) | 400e3 | Base voltage of the bus |
| Types.Frequency | fn (from pfComponent) | SysData.fn | System frequency |
| Types.ActivePower | P_0 (from pfComponent) | 1e6 | Initial active power |
| Types.ReactivePower | Q_0 (from pfComponent) | 0 | Initial reactive power |
| Types.PerUnit | v_0 (from pfComponent) | 1 | Initial voltage magnitude |
| Types.Angle | angle_0 (from pfComponent) | 0 | Initial voltage angle |
| Boolean | displayPF (from pfComponent) | false | Display power flow: |
| Parameter mask | |||
| Boolean | enableS_b (from pfComponent) | false | Enable S_b in parameter list |
| Boolean | enableV_b (from pfComponent) | false | Enable V_b in parameter list |
| Boolean | enablefn (from pfComponent) | false | Enable fn in parameter list |
| Boolean | enableP_0 (from pfComponent) | false | Enable P_0 in parameter list |
| Boolean | enableQ_0 (from pfComponent) | false | Enable Q_0 in parameter list |
| Boolean | enablev_0 (from pfComponent) | false | Enable v_0 in parameter list |
| Boolean | enableangle_0 (from pfComponent) | false | Enable angle_0 in parameter list |
| Boolean | enabledisplayPF (from pfComponent) | false | Enable displayPF in parameter list |
| AVR Disturbance | |||
| Real | height | Disturbance magnitude | |
| Real | tstart | Disturbance time instant | |
| Boolean | refdisturb | Allow disturbance | |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| OpenIPSL.Interfaces.PwPin | pwPin (from Generator) |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| OpenIPSL.Electrical.SystemBase | SysData (from pfComponent) | Must add this line in all models | |
| Types.ActivePower | P (from Generator) | Active power | |
| Types.ReactivePower | Q (from Generator) | Reactive power | |
| OpenIPSL.Electrical.Machines.PSAT.Order4 | gen | ||
| OpenIPSL.Electrical.Controls.PSAT.AVR.AVRTypeII | AVR | ||
| Modelica.Blocks.Sources.Step | step | ||
| Modelica.Blocks.Logical.Switch | switch1 | ||
| Modelica.Blocks.Sources.BooleanConstant | booleanConstant |