modelImpedYDHeat

One terminal impedance base with heat port, 3-phase dq0
Diagram of ImpedYDHeat

Extends from ImpedYDBase (One terminal impedance base, 3-phase dq0), PowerSystems.Interfaces.AddHeat (Additional heat port).

Information

Same as ImpedYDBase, but contains an additional heat port.

Does not contain mass and specific heat. These parameters are expected to belong to the corresponding thermal model. The heat-flow at the connector is given by the total dissipated electric energy of all conductors (not included neutral-to-ground!).

Parameters

TypeNameDefaultDescription
SIpu.Resistancer_n (from ImpedYDBase)1resistance neutral to grd
Parameter Scaling
BooleanpuUnits (from Nominal)true= true, if scaled with nom. values (pu), else scaled with 1 (SI)
Nominal
SI.VoltageV_nom (from Nominal)1nominal Voltage (= base for pu)
SI.ApparentPowerS_nom (from Nominal)1nominal Power (= base for pu)
SI.Frequencyf_nom (from NominalAC)system.f_nomnominal frequency
Initialization
Types.DynamicsdynType (from ImpedYDBase)system.dynTypetransient or steady-state model

Connectors

TypeNameDefaultDescription
Ports.ACdq0_pterm (from Port_p)positive terminal
Thermal_pheat (from AddHeat)heat port

Components

TypeNameDefaultDescription
Topology_ptop (from YDport_p)
PS.Voltagev (from YDport_p)voltage conductor
PS.Currenti (from YDport_p)current conductor
PS.Voltagev_n (from YDport_p)voltage neutral
PS.Currenti_n (from YDport_p)top.i_ncurrent neutral to ground
SI.TemperatureT (from AddHeat)Temperature of conductor
SI.HeatFlowRateQ_flow (from AddHeat)Dissipated heat of conductor