modelVmeter

Voltage meter, 3-phase dq0
Diagram of Vmeter

Extends from Partials.Meter1Base (Meter 1 terminal base, 3-phase dq0).

Information

'Meters' are intended as diagnostic instruments. They allow displaying signals in alternative representations, both in SI-units or in 'pu'.
As they use time-dependent coordinate transforms, use them only when and where needed. Otherwise use 'Sensors'.

Output variables in the chosen reference system:

  v         voltage phase-to-ground
  vpp       voltage phase-to-phase

Optional output variables:

  v_abc     voltage phase-to-ground, abc-inertial system
  vpp_abc   voltage phase-to-phase,  abc-inertial system
  v_norm    norm(v)
  alpha_v   phase(v)

Parameters

TypeNameDefaultDescription
Parameter Scaling
BooleanpuUnits (from Nominal)true= true, if scaled with nom. values (pu), else scaled with 1 (SI)
Nominal
SI.VoltageV_nom (from Nominal)1nominal Voltage (= base for pu)
SI.ApparentPowerS_nom (from Nominal)1nominal Power (= base for pu)
Options
Booleanabc (from Meter1Base)falseabc inertial

Connectors

TypeNameDefaultDescription
Ports.ACdq0_pterm (from Port_p)positive terminal

Components

TypeNameDefaultDescription
SIpu.Voltagev
SIpu.Voltagevpp
SIpu.Voltagev_abctranspose(Park)*v
SIpu.Voltagevpp_abc{v_abc[2], v_abc[3], v_abc[1]} - {v_abc[3], v_abc[1], v_abc[2]}
SIpu.Voltagev_norm
SI.Anglealpha_v