modelFault
Line fault kernel, no terminals
Extends from Partials.FaultBase (Fault kernel base).
Information
Use only as component within complete Fault model.
Clearing criterion: balance heating-cooling.
Contains replaceable model of plasma-arc.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| SI.Resistance | epsR (from FaultBase) | 1e-5 | resistance 'short' |
| SI.Conductance | epsG (from FaultBase) | 1e-5 | conductance 'open' |
| SI.Voltage | Varc | 100 | arc voltage |
| SI.Resistance | R0 | 1 | small-signal resistance |
| SI.Current | Iclear | 10 | self clearing current |
| SI.Time | t_c | 1e-3 | cooling time constant |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| InputVoltage | v (from FaultBase) |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| SI.Current | i (from FaultBase) | ||
| Boolean | on (from FaultBase) | ||
| Boolean | arc |