functionbaseL

Base inductance

Extends from Modelica.Icons.Function (Icon for functions).

Information

Calculates base-inductance depending on the choice of units.

"pu":

  L_base = V_nom*V_nom/(S_nom*omega_nom)
"SI":
  L_base = 1
Note: in contrast to 'baseRL' and 'baseGC' there is NO conversion of reactance X to inductance L.
Therefore the SI-value is 1 and not 1/omega_nom. The function is needed for DC-machines which use L as input instead of X.

Inputs

TypeNameDefaultDescription
BooleanpuUnits= true if pu else SI units
SI.VoltageV_nomnom voltage
SI.ApparentPowerS_nomapparent power
SI.AngularFrequencyomega_nomangular frequency

Outputs

TypeNameDefaultDescription
SI.InductanceL_basebase inductance