modelBreaker
Circuit breaker, immediate action
Extends from Modelica.Electrical.Analog.Interfaces.OnePort (Component with two electrical pins p and n and current i from p to n).
Information
When the current through the breaker goes above Imax, the breaker is tripped open and a message is printed out. The conductance of the breaker is Gclosed in the closed state and Gopen in the open state
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Units.SI.Current | Imax | ||
| String | name | "" | |
| Modelica.Units.SI.Conductance | Gopen | 1e-6 | Conductance when open |
| Modelica.Units.SI.Conductance | Gclosed | 1e6 | Conductance when closed |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| PositivePin | p (from TwoPin) | Positive electrical pin | |
| NegativePin | n (from TwoPin) | Negative electrical pin |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| SI.Voltage | v (from TwoPin) | Voltage drop of the two pins (= p.v - n.v) | |
| SI.Current | i (from OnePort) | Current flowing from pin p to pin n | |
| Boolean | open | State of the breaker | |
| Modelica.Units.SI.Conductance | G | Conductance |