modelHeatingSystem_N_5

Extends from Models.HeatingSystem (Declarative model of a heating system - continuous-time dynamics).

Parameters

TypeNameDefaultDescription
Realpi (from HeatingSystem)Modelica.Constants.pi
IntegerN (from HeatingSystem)3Number of heated units
SI.HeatCapacity[N]Cu (from HeatingSystem)(ones(N) + linspace(0, 1.348, N))*1e7Heat capacity of heated units
SI.HeatCapacityCd (from HeatingSystem)2e6*NHeat capacity of distribution circuit
SI.ThermalConductanceGh (from HeatingSystem)200Thermal conductance of heating elements
SI.ThermalConductanceGu (from HeatingSystem)150Thermal conductance of heated units to the atmosphere
SI.PowerQmax (from HeatingSystem)N*3000Maximum power output of heat generation unit
SI.TemperatureDifferenceTeps (from HeatingSystem)0.5Threshold of heated unit temperature controllers
SI.TemperatureTd0 (from HeatingSystem)343.15Set point of distribution circuit temperature
SI.TemperatureTu0 (from HeatingSystem)293.15Heated unit temperature set point
RealKp (from HeatingSystem)Qmax/4Proportional gain of heat generation unit temperature controller
Reala (from HeatingSystem)50Gain of the histeresis function
Realb (from HeatingSystem)15Slope of the saturation function at the origin

Components

TypeNameDefaultDescription
SI.TemperatureTd (from HeatingSystem)Temperature of the fluid in the distribution system
SI.Temperature[N]Tu (from HeatingSystem)Temperature of individual heated units
Real[N]x (from HeatingSystem)States of heated units temperature controllers
SI.TemperatureText (from HeatingSystem)External temperature
SI.Power[N]Que (from HeatingSystem)Heat flows from heated units to the outside
SI.Power[N]Qh (from HeatingSystem)Heat flows to each heated unit
SI.PowerQd (from HeatingSystem)Heat flow to the distribution system
Real[N]u (from HeatingSystem)Control signals for heaters