modelTransmissionLine
Idealized inductive transmission line model
Information
This model describes an idealized transmission line with purely inductive constant impedance, given by the per-unit parameter Xpu
and by the rated power Pnom.
Parameters
| Type | Name | Default | Description |
| SI.Power | Pnom | | Rated active power |
| SI.PerUnit | Xpu | 0.1 | Inductance in p.u. |
| Initialization |
| SI.Angle | dthetastart | 0 | Start value for the relative voltage angle |
Components
| Type | Name | Default | Description |
| SI.ActivePower | P | port_a.P | Active power flowing from port_a to port_b |
| SI.Angle | dtheta | | Difference between voltage angle at port_a and port_b |