packageCISE

CISE plant models

Extends from Modelica.Icons.ExamplesPackage (Icon for packages containing runnable examples).

Information

This package contain the CISE plant models, described in the papers:
  • F. Casella, A. Leva, "Modelica open library for power plant simulation: design and experimental validation", Proceedings of the 2003 Modelica Conference, Linkö ping, Sweden, 2003.
  • A. Leva, C., Maffezzoni and G. Benelli,, "Validation of drum boiler models through complete dynamic tests", Control Engineering Practice, 7, 1999, pp. 11-26.

The CISEPlant model contains the full plant model, with input connectors for the boundary conditions, and output connectors for the drum pressure and level variable. The CISESim model contains the full plant model, plus signal generators to reproduce the boundary conditions. The other CISESim* models extend the CISESim model with the appropriate numerical values required to reproduce a specific experimental transient.

All simulation are initialized at steady-state by appropriate initial equations.

The CISE-data_2_0.zip file contains the data files of three experimental transients, which can be compared with the simulation results.

Contents

NameDescription
Models
Simulators

Revisions