modelHeader

Header with metal walls for gas flows
Diagram of Header

Extends from Icons.Gas.Mixer.

Information

This model describes a constant volume buffer with metal walls. The metal wall temperature and the heat transfer coefficient between the wall and the fluid are uniform. The wall is thermally insulated from the outside.

If the inlet or the outlet are connected to a bank of tubes, the model can actually represent a collector or a distributor.

Modelling options

The actual gas used in the component is determined by the replaceable Medium package. In the case of multiple component, variable composition gases, the start composition is given by Xstart, whose default value is Medium.reference_X .

Parameters

TypeNameDefaultDescription
Medium.TemperatureTmstart300Metal wall start temperature
SI.VolumeVInner volume
SI.AreaS0Inner surface
SI.CoefficientOfHeatTransfergamma0Heat Transfer Coefficient
SI.HeatCapacityCm0Metal Heat Capacity
BooleanallowFlowReversalsystem.allowFlowReversal= true to allow flow reversal, false restricts to design direction
Initialisation
Medium.AbsolutePressurepstart1e5Pressure start value
Medium.TemperatureTstart300Temperature start value
Medium.MassFraction[Medium.nX]XstartMedium.reference_XStart gas composition
Choices.Init.OptionsinitOptsystem.initOptInitialisation option
BooleannoInitialPressurefalseRemove initial equation on pressure
BooleannoInitialTemperaturefalseRemove initial equation on temperature

Connectors

TypeNameDefaultDescription
FlangeAinlet
FlangeBoutlet
Thermal.HTthermalPort

Components

TypeNameDefaultDescription
Medium.BasePropertiesgas
ThermoPower.SystemsystemSystem wide properties
SI.MassMGas total mass
SI.InternalEnergyEGas total energy
Medium.SpecificEnthalpyhiInlet specific enthalpy
Medium.SpecificEnthalpyhoOutlet specific enthalpy
Medium.MassFraction[Medium.nXi]Xi_iInlet composition
Medium.MassFraction[Medium.nXi]Xi_oOutlet composition
SI.TemperatureTmWall temperature
SI.TimeTrResidence Time

Contents

NameDescription
Medium

Revisions