modelMetalWall

Diagram of MetalWall

Extends from MetalWallFEM (Generic metal wall - 1 radial node and N axial nodes), Modelica.Icons.ObsoleteModel (Icon for classes that are obsolete and will be removed in later versions).

Information

This is the model of a cylindrical tube of solid material.

The heat capacity (which is lumped at the center of the tube thickness) is accounted for, as well as the thermal resistance due to the finite heat conduction coefficient. Longitudinal heat conduction is neglected.

Modelling options

The following options are available:

  • WallRes = false: the thermal resistance of the tube wall is neglected.
  • WallRes = true: the thermal resistance of the tube wall is accounted for.

Parameters

TypeNameDefaultDescription
IntegerN (from MetalWallFEM)2Number of nodes
SI.MassM (from MetalWallFEM)Mass
SI.AreaSint (from MetalWallFEM)Internal surface
SI.AreaSext (from MetalWallFEM)External surface
SI.SpecificHeatCapacitycm (from MetalWallFEM)Specific heat capacity of metal
SI.HeatCapacityCm (from MetalWallFEM)M*cmHeat capacity of the wall
Realpi (from MetalWallFEM)Modelica.Constants.pi
Initialisation
SI.TemperatureTstartbar (from MetalWallFEM)300Avarage temperature
SI.TemperatureTstart1 (from MetalWallFEM)TstartbarTemperature start value - first node
SI.TemperatureTstartN (from MetalWallFEM)TstartbarTemperature start value - last node
SI.Temperature[N]Tstart (from MetalWallFEM)Functions.linspaceExt(Tstart1, TstartN, N)Start value of temperature vector (initialized by default)
ThermoPower.Choices.Init.OptionsinitOpt (from MetalWallFEM)system.initOptInitialisation option

Connectors

TypeNameDefaultDescription
ThermoPower.Thermal.DHTNodesint (from MetalWallFEM)Internal surface
ThermoPower.Thermal.DHTNodesext (from MetalWallFEM)External surface

Components

TypeNameDefaultDescription
ThermoPower.Systemsystem (from MetalWallFEM)System wide properties
Units.AbsoluteTemperature[N]T (from MetalWallFEM)Node temperatures

Revisions