functionf_colebrook_2ph
Fanning friction factor for a two phase water/steam flow
Information
The Fanning friction factor is computed by Colebrook's equation, assuming turbulent, homogeneous two-phase flow. For low Reynolds numbers, the limit value for turbulent flow is returned.
Revision history:
- 1 Oct 2003
by Francesco Casella:
First release.
Inputs
| Type | Name | Default | Description |
|---|---|---|---|
| SI.MassFlowRate | w | ||
| Real | D_A | ||
| Real | e | ||
| SI.DynamicViscosity | mul | ||
| SI.DynamicViscosity | muv | ||
| SI.PerUnit | x |
Outputs
| Type | Name | Default | Description |
|---|---|---|---|
| SI.PerUnit | f |