functionf_colebrook_2ph

Fanning friction factor for a two phase water/steam flow

Information

The Fanning friction factor is computed by Colebrook's equation, assuming turbulent, homogeneous two-phase flow. For low Reynolds numbers, the limit value for turbulent flow is returned.

Revision history:

Inputs

TypeNameDefaultDescription
SI.MassFlowRatew
RealD_A
Reale
SI.DynamicViscositymul
SI.DynamicViscositymuv
SI.PerUnitx

Outputs

TypeNameDefaultDescription
SI.PerUnitf