functionWBCrossedCurrentConvectiveHeatTransferCoefficient
Convective heat transfer coefficient for crossed current heat exchangers
Information
## Copyright © EDF 2002 - 2026 ## ThermoSysPro Version 4.2
Inputs
| Type | Name | Default | Description |
|---|---|---|---|
| Units.SI.Temperature | TFilm | Film temperature | |
| Units.SI.MassFlowRate | Qf | Flue gases mass flow rate | |
| Real | Xh2o | H2O mass fraction in the flue gases | |
| Units.SI.Area | Sgaz | Geometrical parameter | |
| Units.SI.Diameter | Dext | Pipes external diameter | |
| Real | Fa | Pipes position coefficient | |
| Integer | option_interpolation | 1 | 1: linear interpolation - 2: spline interpolation |
Outputs
| Type | Name | Default | Description |
|---|---|---|---|
| Units.SI.CoefficientOfHeatTransfer | Kcfc | Convective heat transfer coefficient for crossed current heat exchanger |
Revisions
Author Baligh El Hefni