modelSynchronousMotor
Synchronous electrical motor
Information
## Copyright © EDF 2002 - 2026 ## ThermoSysPro Version 4.2
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| ThermoSysPro.Units.nonSI.AngularVelocity_rpm | Vrot | 1400. | Nominal rotational speed |
| ThermoSysPro.Units.nonSI.AngularVelocity_rpm | Vrot0 | 0 | Initial rotational speed (active if steady_state_mech=true) |
| Units.SI.Voltage | Ualim | 380. | Voltage |
| Real | D | 10.0 | Damping coefficient (mechanical losses) (n.u.) |
| Units.SI.Inductance | Lm | 1. | Motor nductance |
| Units.SI.Resistance | Rm | 0.00001 | Motor resistance |
| Real | Ki | 1. | Proportionnality coef. between Cm and Im (N.m/A) |
| Units.SI.MomentOfInertia | J | 4. | Motor moment of inertia |
| Boolean | steady_state_mech | true | true: start from steady state - false : start from Vrot0 |
| Boolean | mech_coupling | true | Use mechanical coupling component |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| ThermoSysPro.InstrumentationAndControl.Connectors.InputLogical | marche | ||
| ThermoSysPro.ElectroMechanics.Connectors.MechanichalTorque | C |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Units.SI.AngularVelocity | w | Angular speed | |
| Units.SI.Torque | Cm | Motor torque | |
| Units.SI.Torque | Ctr | Mechanical torque | |
| Units.SI.Current | Im | Current | |
| Units.SI.Voltage | Um | Voltage |
Revisions
Author Daniel Bouskela