modelStaticFluegasesFluegasesExchangerKS

Static flue gases/flue gases heat exchanger with fixed K and S
Diagram of StaticFluegasesFluegasesExchangerKS

Information

## Copyright © EDF 2002 - 2026   
## ThermoSysPro Version 4.2

Parameters

TypeNameDefaultDescription
Units.SI.CoefficientOfHeatTransferK100Global heat exchange coefficient
Units.SI.AreaS10Heat exchange surface
RealDPc0.1Pressure losses in the hot fluid as a percent of the pressure at the inlet
RealDPf0.1Pressure losses in the cold fluid as a percent of the pressure at the inlet

Connectors

TypeNameDefaultDescription
ThermoSysPro.FlueGases.Connectors.FlueGasesOutletSc
ThermoSysPro.FlueGases.Connectors.FlueGasesInletEc
ThermoSysPro.FlueGases.Connectors.FlueGasesInletEf
ThermoSysPro.FlueGases.Connectors.FlueGasesOutletSf
InstrumentationAndControl.Connectors.InputRealKcorrK_correction

Components

TypeNameDefaultDescription
Units.SI.PowerWPower exchanged
Units.SI.TemperatureTecTemperature of the hot fluid at the inlet
Units.SI.TemperatureTscTemperature of the hot fluid at the outlet
Units.SI.TemperatureTefTemperature of the cold fluid at the inlet
Units.SI.TemperatureTsfTemperature of the cold fluid at the outlet
ThermoSysPro.Units.SI.TemperatureDifferenceDT1Delta T at the inlet
ThermoSysPro.Units.SI.TemperatureDifferenceDT2Delta T at the outlet
Units.SI.SpecificHeatCapacityCpfSpecific heat capacity of the cold fluid
Units.SI.SpecificHeatCapacityCpcSpecific heat capacity of the hot fluid
Units.SI.MassFlowRateQcMass flow rate of the hot fluid
Units.SI.MassFlowRateQfMass flow rate of the cold fluid
RealKcorCorrective term for the global heat exchange coefficient

Revisions

Author  

Baligh El Hefni