modelStaticFan
Static fan
Information
## Copyright © EDF 2002 - 2026 ## ThermoSysPro Version 4.2
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| ThermoSysPro.Units.nonSI.AngularVelocity_rpm | VRot | 1400 | Rotational speed |
| ThermoSysPro.Units.nonSI.AngularVelocity_rpm | VRotn | 1400 | Nominal rotational speed |
| Real | rm | 0.85 | Product of the pump mechanical and electrical efficiencies |
| Boolean | adiabatic_compression | false | true: adiabatic compression - false: non adiabatic compression |
| Units.SI.Density | p_rho | 0 | If > 0, fixed fluid density |
| Real | a1 | -52.04 | x^2 coef. of the pump characteristics hn = f(vol_flow) (s2/m5) |
| Real | a2 | -71.735 | x coef. of the pump characteristics hn = f(vol_flow) (s/m2) |
| Real | a3 | 45.59 | Constant coef. of the pump characteristics hn = f(vol_flow) (m) |
| Real | b1 | -8.4818 | x^2 coef. of the pump efficiency characteristics rh = f(vol_flow) (s2/m6) |
| Real | b2 | 4.6593 | x coef. of the pump efficiency characteristics rh = f(vol_flow) (s/m3) |
| Real | b3 | -0.1533 | Constant coef. of the pump efficiency characteristics rh = f(vol_flow) (s.u.) |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| ThermoSysPro.InstrumentationAndControl.Connectors.InputLogical | commandeFan | ||
| Connectors.FlueGasesInlet | C1 | ||
| Connectors.FlueGasesOutlet | C2 | ||
| ThermoSysPro.InstrumentationAndControl.Connectors.InputReal | VRotation |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Real | rh | Hydraulic efficiency | |
| Units.SI.Length | hn | Pump head | |
| Real | R | Ratio VRot/VRotn (s.u.) | |
| Units.SI.MassFlowRate | Q | Mass flow | |
| Units.SI.VolumeFlowRate | Qv | Volumetric flow | |
| Units.SI.Power | Wh | Hydraulic power | |
| Units.SI.Power | Wm | Motor power | |
| Units.SI.Density | rho | Fluid density | |
| ThermoSysPro.Units.SI.PressureDifference | deltaP | Pressure variation between the outlet and the inlet | |
| Units.SI.SpecificEnthalpy | deltaH | Specific enthalpy variation between the outlet and the inlet | |
| Units.SI.AbsolutePressure | P | Fluid average pressure | |
| Units.SI.SpecificEnthalpy | h | Fluid average specific enthalpy | |
| Units.SI.SpecificEnthalpy | h1 | Fluid specific enthalpy in | |
| Units.SI.SpecificEnthalpy | h2 | Fluid specific enthalpy out | |
| Units.SI.Temperature | T | Fluid temperature |
Revisions
Authors Daniel Bouskela Baligh El Hefni