modelControlValve

Control valve
Diagram of ControlValve

Information

## Copyright © EDF 2002 - 2026  
## ThermoSysPro Version 4.2

Parameters

TypeNameDefaultDescription
ThermoSysPro.Units.xSI.CvCvmax5000Maximum CV [USG/min] (active if mode_caract=0)
Real[:,2]caract[0, 0; 1, Cvmax]Position vs. Cv [USG/min] characteristics (active if mode_caract=1)
Integermode_caract00:linear characteristics - 1:characteristics is given by caract[]
Integeroption_interpolation11: linear interpolation - 2: spline interpolation (active if mode_caract=1)
Units.SI.Densityp_rho0If > 0, fixed fluid density

Connectors

TypeNameDefaultDescription
ThermoSysPro.InstrumentationAndControl.Connectors.InputRealOuv
Connectors.FlueGasesInletC1
Connectors.FlueGasesOutletC2

Components

TypeNameDefaultDescription
ThermoSysPro.Units.xSI.CvCvCv [USG/min]
Units.SI.MassFlowRateQMass flow
ThermoSysPro.Units.SI.PressureDifferencedeltaPSingular pressure loss
Units.SI.DensityrhoFluid density
Units.SI.TemperatureTFluid temperature
Units.SI.AbsolutePressurePFluid average pressure

Revisions

Authors  

Daniel Bouskela  
Baligh El Hefni