modelSingularPressureLoss
Singular pressure loss for flue gases
Information
## Copyright © EDF 2002 - 2026 ## ThermoSysPro Version 4.2
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | K | 1.e-3 | Friction pressure loss coefficient |
| Units.SI.Density | p_rho | 0 | If > 0, fixed fluid density |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| ThermoSysPro.FlueGases.Connectors.FlueGasesInlet | C1 | ||
| ThermoSysPro.FlueGases.Connectors.FlueGasesOutlet | C2 |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| ThermoSysPro.Units.SI.PressureDifference | deltaPf | Friction pressure loss | |
| Units.SI.MassFlowRate | Q | Mass flow | |
| Units.SI.Density | rho | Fluid density | |
| Units.SI.Temperature | T | Fluid temperature | |
| Units.SI.AbsolutePressure | P | Average fluid pressure |
Revisions
Authors Daniel Bouskela Baligh El Hefni