modelBoilerSystem

Boiler
Diagram of BoilerSystem

Extends from ThermoSysPro.Fluid.Interfaces.PropertyInterfaces.FlueGasesFluidTypeParameterInterface (Interface to display the flue gases fluid type after parametrization), ThermoSysPro.Fluid.Interfaces.IconColors (Colors of the static, singular and dynamic model icons).

Information

## Copyright © EDF 2002 - 2026   
## ThermoSysPro Version 4.2

Parameters

TypeNameDefaultDescription
Units.SI.TemperatureTsf423.16Flue gases temperature at the outlet
IntegerBoiler_efficiency_type11: Taking into account LHV only - 2: Using the total incoming power
ThermoSysPro.Units.xSI.PressureLossCoefficientKf0.05Flue gases pressure loss coefficient
ThermoSysPro.Units.xSI.PressureLossCoefficientKe1e4Water/steam pressure loss coefficient
Realetacomb1Combustion efficiency (between 0 and 1)
Units.SI.PowerWloss1e5Thermal losses
Units.SI.MassFlowRategamma_diff_ws1e-4Diffusion conductance for the water/steam side (active if diffusion=true in neighbouring volumes)
Booleancontinuous_flow_reversalfalsetrue: continuous flow reversal - false: discontinuous flow reversal
Booleandiffusionfalsetrue: energy balance equation with diffusion - false: energy balance equation without diffusion
Fluid › Fluid properties
FlueGasesFluidTypefgftype (from FlueGasesFluidTypeParameterInterface)FlueGasesFluidType.FlueGasesFlue gases fluid type
IF97RegionregionIF97Region.All_regionsIF97 region (active for IF97 water/steam only)

Connectors

TypeNameDefaultDescription
Interfaces.Connectors.FluidInletInletWaterSteamWater inlet
Interfaces.Connectors.FluidOutletOutletWaterSteamWater/steam outlet
Interfaces.Connectors.FluidOutletOutletFlueGasesFlue gases outlet
Interfaces.Connectors.FluidInletInletFlueGasesFlue gases inlet

Components

TypeNameDefaultDescription
ThermoSysPro.Fluid.Combustion.BoundaryConditions.FuelSourcePQFuel
ThermoSysPro.Fluid.Boilers.FossilFuelBoilerBoiler

Revisions

Author  

Baligh El Hefni