modelDeheaterMixer2

Diagram of DeheaterMixer2

Extends from ThermoSysPro.Fluid.Interfaces.PropertyInterfaces.FluidTypeParameterInterface (Interface to display the fluid type after parametrization), ThermoSysPro.Fluid.Interfaces.IconColors (Colors of the static, singular and dynamic model icons).

Information

## Copyright © EDF 2002 - 2026   
## ThermoSysPro Version 4.2

Parameters

TypeNameDefaultDescription
Units.SI.TemperatureTmax700Maximum fluid temperature
Booleancontinuous_flow_reversalfalsetrue: continuous flow reversal - false: discontinuous flow reversal
Booleandiffusionfalsetrue: energy balance equation with diffusion - false: energy balance equation without diffusion
Fluid › Fluid properties
FluidTypeftype (from FluidTypeParameterInterface)FluidType.WaterSteamFluid type
IF97RegionregionIF97Region.All_regionsIF97 region (active for IF97 water/steam only)

Connectors

TypeNameDefaultDescription
ThermoSysPro.Fluid.Interfaces.Connectors.FluidInletCe_mix
ThermoSysPro.Fluid.Interfaces.Connectors.FluidOutletCs
ThermoSysPro.Fluid.Interfaces.Connectors.FluidInletCe

Components

TypeNameDefaultDescription
Integerfluid1 (from FluidTypeParameterInterface)Integer(ftype)Fluid number
Units.SI.AbsolutePressurePFluid pressure
Units.SI.SpecificEnthalpyhFluid specific enthalpy
Units.SI.TemperatureTFluid temperature
Units.SI.SpecificEnthalpyhmaxMaximum fluid specific enthalpy
FluidType[4]fluidsFluids mixing in volume
ThermoSysPro.Units.SI.MassFractionXco2CO2 mass fraction
ThermoSysPro.Units.SI.MassFractionXh2oH20 mass fraction
ThermoSysPro.Units.SI.MassFractionXo2O2 mass fraction
ThermoSysPro.Units.SI.MassFractionXso2SO2 mass fraction
Units.SI.PowerJeThermal power diffusion from inlet e
Units.SI.PowerJe_mixThermal power diffusion from inlet e_mix
Units.SI.PowerJsThermal power diffusion from outlet s
Units.SI.PowerJTotal thermal power diffusion
Units.SI.MassFlowRategamma_eDiffusion conductance for inlet e
Units.SI.MassFlowRategamma_e_mixDiffusion conductance for inlet e_mix
Units.SI.MassFlowRategamma_sDiffusion conductance for outlet s
RealreValue of r(Q/gamma) for inlet e
Realre_mixValue of r(Q/gamma) for inlet e_mix
RealrsValue of r(Q/gamma) for outlet s

Revisions

Authors  

Baligh El Hefni  
Daniel Bouskela