modelMixer8
Mixer with eight inlets
Extends from ThermoSysPro.Fluid.Interfaces.PropertyInterfaces.FluidTypeParameterInterface (Interface to display the fluid type after parametrization), ThermoSysPro.Fluid.Interfaces.IconColors (Colors of the static, singular and dynamic model icons).
Information
## Copyright © EDF 2002 - 2026 ## ThermoSysPro Version 4.2 This component model is documented in Sect. 14.7 of the ThermoSysPro book.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Boolean | continuous_flow_reversal | false | true: continuous flow reversal - false: discontinuous flow reversal |
| Boolean | diffusion | false | true: energy balance equation with diffusion - false: energy balance equation without diffusion |
| Fluid › Fluid properties | |||
| FluidType | ftype (from FluidTypeParameterInterface) | FluidType.WaterSteam | Fluid type |
| IF97Region | region | IF97Region.All_regions | IF97 region (active for IF97 water/steam only) |
Connectors
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Integer | fluid1 (from FluidTypeParameterInterface) | Integer(ftype) | Fluid number |
| Units.SI.AbsolutePressure | P | Fluid pressure | |
| Units.SI.SpecificEnthalpy | h | Fluid specific enthalpy | |
| Units.SI.Temperature | T | Fluid temperature | |
| FluidType[10] | fluids | Fluids mixing in volume | |
| ThermoSysPro.Units.SI.MassFraction | Xco2 | CO2 mass fraction | |
| ThermoSysPro.Units.SI.MassFraction | Xh2o | H20 mass fraction | |
| ThermoSysPro.Units.SI.MassFraction | Xo2 | O2 mass fraction | |
| ThermoSysPro.Units.SI.MassFraction | Xso2 | SO2 mass fraction | |
| Units.SI.Power | Je1 | Thermal power diffusion from inlet e1 | |
| Units.SI.Power | Je2 | Thermal power diffusion from inlet e2 | |
| Units.SI.Power | Je3 | Thermal power diffusion from inlet e3 | |
| Units.SI.Power | Je4 | Thermal power diffusion from inlet e4 | |
| Units.SI.Power | Je5 | Thermal power diffusion from inlet e5 | |
| Units.SI.Power | Je6 | Thermal power diffusion from inlet e6 | |
| Units.SI.Power | Je7 | Thermal power diffusion from inlet e7 | |
| Units.SI.Power | Je8 | Thermal power diffusion from inlet e8 | |
| Units.SI.Power | Js | Thermal power diffusion from outlet s | |
| Units.SI.Power | J | Total thermal power diffusion | |
| Units.SI.MassFlowRate | gamma_e1 | Diffusion conductance for inlet e1 | |
| Units.SI.MassFlowRate | gamma_e2 | Diffusion conductance for inlet e2 | |
| Units.SI.MassFlowRate | gamma_e3 | Diffusion conductance for inlet e3 | |
| Units.SI.MassFlowRate | gamma_e4 | Diffusion conductance for inlet e4 | |
| Units.SI.MassFlowRate | gamma_e5 | Diffusion conductance for inlet e5 | |
| Units.SI.MassFlowRate | gamma_e6 | Diffusion conductance for inlet e6 | |
| Units.SI.MassFlowRate | gamma_e7 | Diffusion conductance for inlet e7 | |
| Units.SI.MassFlowRate | gamma_e8 | Diffusion conductance for inlet e8 | |
| Units.SI.MassFlowRate | gamma_s | Diffusion conductance for outlet s | |
| Real | re1 | Value of r(Q/gamma) for inlet e1 | |
| Real | re2 | Value of r(Q/gamma) for inlet e2 | |
| Real | re3 | Value of r(Q/gamma) for inlet e3 | |
| Real | re4 | Value of r(Q/gamma) for inlet e4 | |
| Real | re5 | Value of r(Q/gamma) for inlet e5 | |
| Real | re6 | Value of r(Q/gamma) for inlet e6 | |
| Real | re7 | Value of r(Q/gamma) for inlet e7 | |
| Real | re8 | Value of r(Q/gamma) for inlet e8 | |
| Real | rs | Value of r(Q/gamma) for outlet s |
Revisions
Authors Baligh El Hefni Daniel Bouskela