modelSteamDryer
Steam dryer
Extends from ThermoSysPro.Fluid.Interfaces.PropertyInterfaces.WaterSteamFluidTypeParameterInterface (Interface to display the water/steam fluid type after parametrization), ThermoSysPro.Fluid.Interfaces.IconColors (Colors of the static, singular and dynamic model icons).
Information
## Copyright © EDF 2002 - 2026 ## ThermoSysPro Version 4.2 This component model is documented in Sect. 14.9 of the ThermoSysPro book.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | eta | 1 | Steam dryer efficiency (0 <= eta <= 1) |
| Boolean | continuous_flow_reversal | false | true: continuous flow reversal - false: discontinuous flow reversal |
| Boolean | diffusion | false | true: energy balance equation with diffusion - false: energy balance equation without diffusion |
| Fluid › Fluid properties | |||
| WaterSteamFluidType | wsftype (from WaterSteamFluidTypeParameterInterface) | WaterSteamFluidType.WaterSteam | Water/steam fluid type |
| IF97Region | region_e | IF97Region.All_regions | IF97 region at the inlet (active for IF97 water/steam only) |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| ThermoSysPro.Fluid.Interfaces.Connectors.FluidInlet | Cev | ||
| ThermoSysPro.Fluid.Interfaces.Connectors.FluidOutlet | Csv | ||
| ThermoSysPro.Fluid.Interfaces.Connectors.FluidOutlet | Csl |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Units.SI.AbsolutePressure | P | Fluid pressure | |
| Units.SI.SpecificEnthalpy | h | Fluid specific enthalpy | |
| Real | xe | Vapor mass fraction at the inlet | |
| FluidType[4] | fluids | Fluids mixing in volume | |
| ThermoSysPro.Units.SI.MassFraction | Xco2 | CO2 mass fraction | |
| ThermoSysPro.Units.SI.MassFraction | Xh2o | H20 mass fraction | |
| ThermoSysPro.Units.SI.MassFraction | Xo2 | O2 mass fraction | |
| ThermoSysPro.Units.SI.MassFraction | Xso2 | SO2 mass fraction | |
| Units.SI.Power | Jev | Thermal power diffusion from inlet ev | |
| Units.SI.Power | Jsv | Thermal power diffusion from outlet sv | |
| Units.SI.Power | Jsl | Thermal power diffusion from outlet sl | |
| Units.SI.Power | J | Total thermal power diffusion | |
| Units.SI.MassFlowRate | gamma_ev | Diffusion conductance for inlet ev | |
| Units.SI.MassFlowRate | gamma_sv | Diffusion conductance for outlet sv | |
| Units.SI.MassFlowRate | gamma_sl | Diffusion conductance for outlet sl | |
| Real | rev | Value of r(Q/gamma) for inlet ev | |
| Real | rsv | Value of r(Q/gamma) for outlet sv | |
| Real | rsl | Value of r(Q/gamma) for outlet sl | |
| ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_ph | proe | ||
| ThermoSysPro.Properties.WaterSteam.Common.PropThermoSat | lsat1 | ||
| ThermoSysPro.Properties.WaterSteam.Common.PropThermoSat | vsat1 |
Revisions
Authors Baligh El Hefni Daniel Bouskela