| ThermoSysPro.Units.nonSI.AngularVelocity_rpm | N | 1400 | Pump angular velocity in rpm (active if input M is not connected) |
| ThermoSysPro.Units.nonSI.AngularVelocity_rpm | N_nom | 1400 | Nominal angular velocity in rpm |
| Units.SI.MomentOfInertia | J | 10 | Rotating masses moment of inertia (active if dynamic_mech_equation=true) |
| Units.SI.Volume | V | 1 | Pump volume (active if dynamic_energy_balance=true) |
| Boolean | dynamic_mech_equation | false | true: dynamic mechanical equation - false: static mechanical equation (active if input M is connected) |
| Boolean | dynamic_energy_balance | false | true: dynamic energy balance equation - false: static energy balance equation |
| Units.SI.MassFlowRate | gamma_diff | 1e-4 | Diffusion conductance (active if diffusion=true in neighbouring volumes) |
| Integer | mode_car | 2 | 1:nominal values and coef. c given by parameters - 2:nominal values and coef. c computed from semi-parabolic characteristics |
| Integer | mode_car_hn | 2 | 1:complete pump head characteristics - 2:semi-parabolic pump head characteristics |
| Integer | mode_car_Cr | 2 | 1:complete torque characteristics - 2:analytic formula |
| Units.SI.VolumeFlowRate | Qv_nom_p | 0.4781 | Nominal volumetric flow (active if mode_car=1) |
| Units.SI.Height | hn_nom_p | 22.879 | Nominal pump head (active if mode_car=1) |
| Units.SI.Height | rh_nom_p | 0.863 | Nominal pump efficiency (active if mode_car=1) |
| Real[:] | F_t | {0.634, 0.643, 0.646, 0.640, 0.629, 0.613, 0.595, 0.575, 0.552, 0.533, 0.516, 0.505, 0.504, 0.510, 0.512, 0.522, 0.539, 0.559, 0.580, 0.601, 0.630, 0.662, 0.692, 0.722, 0.753, 0.782, 0.808, 0.832, 0.857, 0.879, 0.904, 0.930, 0.959, 0.996, 1.027, 1.060, 1.090, 1.124, 1.165, 1.204, 1.238, 1.258, 1.271, 1.282, 1.288, 1.281, 1.260, 1.225, 1.172, 1.107, 1.031, 0.942, 0.842, 0.733, 0.617, 0.500, 0.368, 0.240, 0.125, 0.011, -0.102, -0.168, -0.255, -0.342, -0.423, -0.494, -0.556, -0.620, -0.655, -0.670, -0.670, -0.660, -0.655, -0.640, -0.600, -0.570, -0.520, -0.470, -0.430, -0.360, -0.275, -0.160, -0.040, 0.130, 0.295, 0.430, 0.550, 0.620, 0.634} | Head characteristics (active if mode_car_hn=1) |
| Real[:] | G_t | {-0.684, -0.547, -0.414, -0.292, -0.187, -0.105, -0.053, -0.012, 0.042, 0.097, 0.156, 0.227, 0.300, 0.371, 0.444, 0.522, 0.596, 0.672, 0.738, 0.763, 0.797, 0.837, 0.865, 0.883, 0.886, 0.877, 0.859, 0.838, 0.804, 0.758, 0.703, 0.645, 0.583, 0.520, 0.454, 0.408, 0.370, 0.343, 0.331, 0.329, 0.338, 0.354, 0.372, 0.405, 0.450, 0.486, 0.520, 0.552, 0.579, 0.603, 0.616, 0.617, 0.606, 0.582, 0.546, 0.500, 0.432, 0.360, 0.288, 0.214, 0.123, 0.037, -0.053, -0.161, -0.248, -0.314, -0.372, -0.580, -0.740, -0.880, -1.000, -1.120, -1.250, -1.370, -1.490, -1.590, -1.660, -1.690, -1.770, -1.650, -1.590, -1.520, -1.420, -1.320, -1.230, -1.100, -0.980, -0.820, -0.684} | Torque characteristics (active if mode_car_Cr=1) |
| Real | c_p | 1.288 | Dimensionless coef. of the semi-parabolic pump head characteristics (active if mode_car=1 and mode_car_hn=2) |
| Real | b | 2 | Dimensionless coef. of the parabolic pump efficiency characteristics |
| Real[2] | hn_coef | {-88.67, 43.15} | Coef. of the semi-parabolic pump head characteristics (active if mode_car=2) |
| Real[2] | rh_coef | {-3.7751, 3.61} | Coef. of the parabolic pump efficiency characteristics (active if mode_car=2) |
| Fluid › Fluid properties |
| Units.SI.Density | p_rho | 0 | If > 0, fixed fluid density |
| IF97Region | region | IF97Region.All_regions | IF97 region (active for IF97 water/steam only) |