modelHeatPumpCompressor

Heat pump compressor
Diagram of HeatPumpCompressor

Information

## Copyright © EDF 2002 - 2026   
## ThermoSysPro Version 4.2

Parameters

TypeNameDefaultDescription
Realpi10.0Compression factor (Ps/Pe)
Realeta0.85Isentropic efficiency
Units.SI.PowerW_fric0.0Power losses due to hydrodynamic friction (percent)
Units.SI.MassFlowRategamma_diff1e-4Diffusion conductance (active if diffusion=true in neighbouring volumes)

Connectors

TypeNameDefaultDescription
Interfaces.Connectors.FluidInletC1
Interfaces.Connectors.FluidOutletC2

Components

TypeNameDefaultDescription
Units.SI.PowerWMechanical power delivered to the compressor
Units.SI.MassFlowRateQMass flow rate
Units.SI.SpecificEnthalpyHisFluid specific enthalpy after isentropic compression
Units.SI.AbsolutePressurePeInlet pressure
Units.SI.AbsolutePressurePsOutlet pressure
Units.SI.TemperatureTeInlet temperature
Units.SI.TemperatureTsOutlet temperature
RealxmAverage vapor mass fraction
FluidTypeftypeFluid type
IntegerfluidInteger(ftype)Fluid number
ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_phproe
ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_phpros
ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_psprops

Revisions

Authors  

Benoît Bride  
Daniel Bouskela