Parameters

TypeNameDefaultDescription
ThermoSysPro.Units.nonSI.AngularVelocity_rpmVRot1400Fixed rotational speed (active if fixed_rot_or_power=1 and rpm_or_mpower connector not connected)
Units.SI.PowerMPower0.1e6Fixed mechanical power (active if fixed_rot_or_power=2 and rpm_or_mpower connector not connected)
ThermoSysPro.Units.nonSI.AngularVelocity_rpmVRotn1400Nominal rotational speed
Realrm0.85Product of the pump mechanical and electrical efficiencies
Integerfixed_rot_or_power11: fixed rotational speed - 2: fixed mechanical power
Booleanadiabatic_compressionfalsetrue: compression at constant enthalpy - false: compression with varying enthalpy
Units.SI.MassFlowRategamma_diff1e-4Diffusion conductance (active if diffusion=true in neighbouring volumes)
Reala1-88.67x^2 coef. of the pump characteristics hn = f(vol_flow) (s2/m5)
Reala20x coef. of the pump characteristics hn = f(vol_flow) (s/m2)
Reala343.15Constant coef. of the pump characteristics hn = f(vol_flow) (m)
Realb1-3.7751x^2 coef. of the pump efficiency characteristics rh = f(vol_flow) (s2/m6)
Realb23.61x coef. of the pump efficiency characteristics rh = f(vol_flow) (s/m3)
Realb3-0.0075464Constant coef. of the pump efficiency characteristics rh = f(vol_flow) (s.u.)
Fluid › Fluid properties
Units.SI.Densityp_rho0If > 0, fixed fluid density
IF97RegionregionIF97Region.All_regionsIF97 region (active for IF97 water/steam only)

Connectors

TypeNameDefaultDescription
ThermoSysPro.Fluid.Interfaces.Connectors.FluidInletC1
ThermoSysPro.Fluid.Interfaces.Connectors.FluidOutletC2
ThermoSysPro.InstrumentationAndControl.Connectors.InputRealrpm_or_mpower

Components

TypeNameDefaultDescription
RealrhHydraulic efficiency
Units.SI.HeighthnPump head
RealRReduced rotational speed
Units.SI.MassFlowRateQMass flow rate
Units.SI.VolumeFlowRateQvVolume flow rate
Units.SI.PowerWhHydraulic power
Units.SI.PowerWmMechanical power
ThermoSysPro.Units.nonSI.AngularVelocity_rpmVrRotational speed
Units.SI.DensityrhoFluid density
ThermoSysPro.Units.SI.PressureDifferencedeltaPPressure variation between the outlet and the inlet
Units.SI.SpecificEnthalpydeltaHSpecific enthalpy variation between the outlet and the inlet
Units.SI.AbsolutePressurePmFluid average pressure
Units.SI.SpecificEnthalpyhFluid average specific enthalpy
FluidTypeftypeFluid type
IntegerfluidInteger(ftype)Fluid number

Revisions

Authors  

Daniel Bouskela  
Baligh El Hefni