modelDesorberWaterLiBr

Water LiBr solution desorber with water heating
Diagram of DesorberWaterLiBr

Information

## Copyright © EDF 2002 - 2026  


## ThermoSysPro Version 4.2

Parameters

TypeNameDefaultDescription
RealEff0.65Thermal exchange efficiency (=W/Wmax)
ThermoSysPro.Units.SI.PressureDifferenceDPc0Pressure losses in the hot fluid a a percent of the pressure at the inlet
RealPth0.15Thermal losses fraction (=losses/W)

Connectors

TypeNameDefaultDescription
ThermoSysPro.WaterSteam.Connectors.FluidInletEc
ThermoSysPro.WaterSteam.Connectors.FluidOutletSvap
ThermoSysPro.WaterSteam.Connectors.FluidOutletSc
ThermoSysPro.WaterSolution.Connectors.WaterSolutionInletEf
ThermoSysPro.WaterSolution.Connectors.WaterSolutionOutletSf

Components

TypeNameDefaultDescription
Units.SI.PowerWPower exchnaged with the solution
Units.SI.PowerWpthThermal losses power
Units.SI.PowerWtotHot water total power
Units.SI.PowerWmaxfMaximum power acceptable by the solution
Units.SI.PowerWmaxcMaximum power releasable by the hot water
Units.SI.TemperatureTsatcHot water saturation temperature at the outlet
Units.SI.SpecificEnthalpyHmincMinimum specific enthalpy reachable by the hot water
RealXminMinimum mass fraction reachable by the solution
Units.SI.MassFlowRateQs_minMinimum solution mass flow rate at the outlet
Units.SI.MassFlowRateQv_maxMaximum steam mass flow rate at the outlet
Units.SI.PowerWmaxMaximum power exchangeable
ThermoSysPro.Units.SI.TemperatureDifferenceDTmDifferences of the average temperatures between the hot and cold sides
ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_phproce
ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_phprocs
ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_phprovap

Revisions

Author  

Benoît Bride