modelHeatNetworkPipe

Static pipe with thermal losses and singular pressure losses
Diagram of HeatNetworkPipe

Information

## Copyright © EDF 2002 - 2026  


## ThermoSysPro Version 4.2

Parameters

TypeNameDefaultDescription
Units.SI.LengthL10Pipe length
Units.SI.DiameterD0.2Pipe internal diameter
Units.SI.Lengthe0.05Wall thickness
Realrugosrel0Pipe roughness
Units.SI.Lengthz10Pipe altitude at the inlet
Units.SI.Lengthz20Pipe altitude at the outlet
Units.SI.TemperatureTamb293Ambient temperature
Units.SI.CoefficientOfHeatTransferK0.1Heat exchange coefficient with ambient
ThermoSysPro.Units.xSI.PressureLossCoefficientKs1000Singular pressure losses coefficient
Booleancontinuous_flow_reversalfalsetrue: continuous flow reversal - false: discontinuous flow reversal
Units.SI.Densityp_rho0If > 0, fixed fluid density
Integermode0IF97 region. 1:liquid - 2:steam - 4:saturation line - 0:automatic

Connectors

TypeNameDefaultDescription
ThermoSysPro.WaterSteam.Connectors.FluidInletC1
ThermoSysPro.WaterSteam.Connectors.FluidOutletC2

Components

TypeNameDefaultDescription
Units.SI.PowerWlossThermal losses at ambient conditions
RealkhiHydraulic pressure loss coefficient
ThermoSysPro.Units.SI.PressureDifferencedeltaPrRegular pressure losses
ThermoSysPro.Units.SI.PressureDifferencedeltaPTotal pressure losses
ThermoSysPro.Units.SI.PressureDifferencedeltaPsSingular pressure losses
Units.SI.MassFlowRateQMass flow rate
Units.SI.ReynoldsNumberReReynolds number
Units.SI.ReynoldsNumberRelimLimit Reynolds number
ReallambdaFriction pressure loss coefficient
Units.SI.DensityrhoFluid density
Units.SI.DynamicViscositymuFluid dynamic viscosity
Units.SI.TemperatureTFluid temperature
Units.SI.AbsolutePressurePmFluid average pressure
Units.SI.SpecificEnthalpyhmFluid average specific enthalpy
ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_phpro

Revisions

Author  

Benoît Bride