modelDecayHeat

Calculation of the decay heat given by the decay of the fission products in the core of the nuclear reactor
Diagram of DecayHeat

Information

## Copyright © EDF 2002 - 2026  


## ThermoSysPro Version 4.2

Parameters

TypeNameDefaultDescription
Real[:]Kris{0.0251, 0.01654, 0.02586}Fraction of the power associated to group i
Real[:]Tris{15, 137, 2910}Time constant associated to group i (s)
Booleansteady_statetrueInitialize the decay heat at equilibrium

Connectors

TypeNameDefaultDescription
ThermoSysPro.InstrumentationAndControl.Connectors.InputRealPneutrons
ThermoSysPro.InstrumentationAndControl.Connectors.OutputRealDecayHeat

Components

TypeNameDefaultDescription
ThermoSysPro.Units.SI.PowerPneutTotal neutronic power (W)
ThermoSysPro.Units.SI.PowerPresTotTotal decay heat (W)
ThermoSysPro.Units.SI.Power[N]PresResidual power associated to the groups of radio-isotopes (W)