functionderThermalConductivity_derT_derrho
der(Thermal Conductivity) computation for Dry Air Ideal Gas (inputs: T, rho, der(T), der(rho))
Information
## Copyright © EDF 2002 - 2025 ## ThermoSysPro Version 4.2
Inputs
| Type | Name | Default | Description |
|---|---|---|---|
| Units.SI.Temperature | T | Temperature (K) | |
| Units.SI.Density | rho | Density (kg/m3) | |
| Real | der_T | Temperature time derivative (K/s) | |
| Real | der_rho | Density time derivative (kg/m3/s) |
Outputs
| Type | Name | Default | Description |
|---|---|---|---|
| Real | der_k | thermal conductivity time derivative (W/m/K/s) |