modelStaticCondenser

Static condenser
Diagram of StaticCondenser

Information

## Copyright © EDF 2002 - 2026   
## ThermoSysPro Version 4.2  
This component model is documented in Sect. 9.7.1 of the ThermoSysPro book.   
# Static condenser   

This condenser is a large shell-and-tube heat exchanger. It is composed of a bundle of circular tubes mounted in a cavity. The steam in the cavity condensates due to the cooling water flow in the tube bundle. The condenser is positioned at the outlet of the steam turbine in order to receive a large flow rate of low-pressure steam. The steam condensation heat is evacuated by external cooling water pumped through the condenser tube bundle. The condensate at the outlet is pumped and sent into feed water heaters.  

Following assumptions are made in the model:  
- the efficiency of the condenser is equal to 1 (all the steam is condensed).  
- the energy accumulation in the wall is neglected.  
- the hot fluid is assumed to stay at saturation temperature in the condensation zone (no desuperheating zone and no subcooled zone).  

The latter assumption is valid when the condenser is under normal operating conditions: the steam coming from the turbine and the outgoing condensate are at saturation temperature. When superheated steam is directly sent to the condenser, the [dynamic condenser model](modelica://ThermoSysPro.WaterSteam.HeatExchangers.DynamicCondenser) is more appropriate.  

## Modelica component model  

The equations mentioned below are implemented in the component *StaticCondenser*, located in the *WaterSteam.HeatExchangers* sub-library.   
This component has 6 connectors:  
- Cee: cooling water inlet,  
- Cse: cooling water outlet,  
- Cex: extraction water outlet,  
- Cvt: turbine outlet, employed as inlet,  
- Cep: drain inlet,  
- Cev: vapor outlet.  
   
![modelica://ThermoSysPro/UsersGuide/Documentation/ThermoSysPro.WaterSteam.HeatExchangers.StaticCondenser.svg](modelica://ThermoSysPro/UsersGuide/Documentation/ThermoSysPro.WaterSteam.HeatExchangers.StaticCondenser.svg)  

## Nomenclature  

| Symbol| Description| Unit| Definition| Modelica name |  
| :----------------------------------- | :------------------------------------------------------------------------------------------- | :------------------------------------------- | :---------------------------------------------------------------------- | :----------- |  
| \\(A\\)| Heat exchange surface| \\(\mathrm{m}^{2}\\)|| SCO |  
| \\(C\\)| Fouling coefficient| \\(-\\)|| COP |  
| \\(C\_{\text {ref }}\\)| Reference fouling coefficient| \\(-\\)|| COPR |  
| \\(h\_{\mathrm{c}, \mathrm{i}}\\)| Cold fluid specific enthalpy at the inlet| \\(\mathrm{J} / \mathrm{kg}\\)|| Cee.h |  
| \\(h\_{\mathrm{c}, \mathrm{o}}\\)| Cold fluid specific enthalpy at the outlet| \\(\mathrm{J} / \mathrm{kg}\\)|| Cse.h |  
| \\(h\_{\mathrm{d}, \mathrm{i}}\\)| Specific enthalpy at the inlet \(from drain\)| \\(\mathrm{J} / \mathrm{kg}\\)|| Cep.h |  
| \\(h^{\mathrm{h}}\\)| Hot fluids mixing specific enthalpy| \\(\mathrm{J} / \mathrm{kg}\\)|| Hmv |  
| \\(h\_{l,0}\\)| Liquid specific enthalpy at the outlet of the condenser \(drain\)| \\(\mathrm{J} / \mathrm{kg}\\)| \\(h\_{l}^{\mathrm{sat}}+\frac{\left\(P\_{\mathrm{b}}-P\right\)}{\rho\_{l}}\\) | Cex.h |  
| \\(h\_{l}^{\text {sat }}\\)| Hot fluid saturation enthalpy of the liquid| \\(\mathrm{J} / \mathrm{kg}\\)|| lsat1.h |  
| \\(h\_{\mathrm{t}, \mathrm{i}}\\)| Specific enthalpy of the steam coming from the turbine| \\(\mathrm{J} / \mathrm{kg}\\)|| Cvt.h |  
| \\(h\_{\mathrm{v}, \mathrm{i}}\\)| Specific enthalpy of the steam coming from the boiler outlet or from the turbine inlet valve | \\(\mathrm{J} / \mathrm{kg}\\)|| Cev.h |  
| \\(h\_{\text {cond }}\\)| Heat exchange coefficient: correlation given by the manufacturers| \\(\mathrm{W} / \mathrm{m}^{2} / \mathrm{K}\\) || XKCO |  
| \\(K\_{\text {cond }}\\)| Reference heat exchange coefficient| \\(\mathrm{W} / \mathrm{m}^{2} / \mathrm{K}\\) || KCO |  
| \\(m\_{\mathrm{c}}\\)| Cold fluid \(water\) mass flow rate| \\(\mathrm{kg} / \mathrm{s}\\)|| Cee.Q |  
| \\(m\_{\mathrm{c}, \mathrm{ref}}\\)| Cold fluid \(water\) reference mass flow rate| \\(\mathrm{kg} / \mathrm{s}\\)|| QC0 |  
| \\(\dot{m}\_{\mathrm{d}, \mathrm{i}}\\) | Water mass flow rate at the inlet \(drain\)| \\(\mathrm{kg} / \mathrm{s}\\)|| Cep.Q |  
| \\(\dot{m}\_{\mathrm{d}, \mathrm{o}}\\) | Water mass flow rate at the outlet of the condenser| \\(\mathrm{kg} / \mathrm{s}\\)|| Cex.Q |  
| \\(m\_{\mathrm{t}, \mathrm{i}}\\)| Mass flow rate of the steam coming from the turbine| \\(\mathrm{kg} / \mathrm{s}\\)|| Cvt.Q |  
| \\(m\_{\mathrm{v}, \mathrm{i}}\\)| Mass flow rate of the steam coming from the boiler outlet or from the turbine inlet valve| \\(\mathrm{kg} / \mathrm{s}\\)|| Cev.Q |  
| \\(P\\)| Steam pressure inside the condenser \(cavity pressure\)| \\(\mathrm{Pa}\\)|| Pcond |  
| \\(P\_{\mathrm{b}}\\)| Fluid pressure at the bottom of the cavity \(drain outlet\)| \\(\mathrm{Pa}\\)| \\(P+\rho\_{l} \cdot g \cdot z\_{l}\\)| Cex.P |  
| \\(P\_{\mathrm{c}, \mathrm{i}}\\)| Cold fluid pressure at the inlet| \\(\mathrm{Pa}\\)|| Cee.P |  
| \\(P\_{\mathrm{c}, \mathrm{o}}\\)| Cold fluid pressure at the outlet| \\(\mathrm{Pa}\\)|| Cse.P |  
| \\(T\_{\mathrm{c}, \mathrm{i}}\\)| Cold fluid \(water\) temperature at the inlet| \\(\mathrm{K}\\)|| Tee |  
| \\(T\_{\mathrm{c}, \mathrm{o}}\\)| Cold fluid \(water\) temperature at the outlet| \\(\mathrm{K}\\)|| Tse |  
| \\(T\_{\mathrm{c}, \text { ref }}\\)| Cold fluid \(water\) reference temperature| \\(\mathrm{K}\\)|| - |  
| \\(T^{\text {sat }}\\)| Saturation temperature| \\(\mathrm{K}\\)|| lsat1.T, vsat1.T |  
| \\(W\\)| Heat power released to the cold fluid \(thermal power exchanged\)| \\(\mathrm{W}\\)|| W |  
| \\(z\_{l}\\)| Water level in the condenser| \\(\mathrm{m}\\)|| z |  
| \\(\Delta P\_{\mathrm{c}}\\)| Cold fluid pressure loss between the inlet and the outlet| \\(\mathrm{Pa}\\)| \\(P\_{\mathrm{c}, \mathrm{i}}-P\_{\mathrm{c}, \mathrm{o}}\\)| - |  
| \\(\Lambda\_{\mathrm{c}}\\)| Cold fluid friction pressure loss coefficient| \\(\mathrm{m}^{-4}\\)|| CPCE |  
| \\(\rho\_{\mathrm{c}}\\)| Cold fluid density| \\(\mathrm{kg} / \mathrm{m}^{3}\\)|| rho_ee |  
| \\(\rho\_{l}\\)| Water density at the extraction point \(i.e., at the liquid outlet of the condenser\)| \\(\mathrm{kg} / \mathrm{m}^{3}\\)|| rho_ex |  


## Governing equations  

### Power received by the cold fluid  


    
    

- Validity domain:   
   
 \\(\forall \dot{m}\_{\mathrm{c}}\\)  

- Mathematical formulation:   
   
 $$W=\dot{m}\_{\mathrm{c}} \cdot\left\(h\_{\mathrm{c}, \mathrm{o}}-h\_{\mathrm{c}, \mathrm{i}}\right\)$$  

- Comments:   
   



### Mass balance equation of the hot fluids  


    
    

- Validity domain:   
   
 \\(\forall \dot{m}\_{t, i}, \forall \dot{m}\_{v, i}\\) and \\(\forall \dot{m}\_{\mathrm{d}, \mathrm{i}}\\)  

- Mathematical formulation:   
   
 $$\dot{m}\_{\mathrm{d}, \mathrm{o}}=\dot{m}\_{\mathrm{t}, \mathrm{i}}+\dot{m}\_{\mathrm{v}, \mathrm{i}}+\dot{m}\_{\mathrm{d}, \mathrm{i}}$$   

- Comments:   
   
 There are three sources of hot fluids the turbine, the boiler outlet or turbine inlet valve, and the drain.  


### Specific mixing enthalpy of the hot fluids  


    
    

- Validity domain:   
   
 \\(\dot{m}\_{\mathrm{d}, \mathrm{o}} \neq 0, \forall \dot{m}\_{\mathrm{t}, \mathrm{i}}, \forall \dot{m}\_{\mathrm{v}, \mathrm{i}}\\) and \\(\forall \dot{m}\_{\mathrm{d}, \mathrm{i}}\\)  

- Mathematical formulation:   
   
 $$\dot{m}\_{\mathrm{d}, \mathrm{o}} \cdot h^{\mathrm{h}}=\dot{m}\_{\mathrm{t}, \mathrm{i}} \cdot h\_{\mathrm{t}, \mathrm{i}}+\dot{m}\_{\mathrm{v}, \mathrm{i}} \cdot h\_{\mathrm{v}, \mathrm{i}}+\dot{m}\_{\mathrm{d}, \mathrm{i}} \cdot h\_{\mathrm{d}, \mathrm{i}}$$  

- Comments:   
   
 The mixing enthalpy is used to compute the properties of the hot fluid inside the condenser  


### Energy released during the condensation of the steam at the inlets  


    
    

- Validity domain:   
   
 \\(\forall \dot{m}\_{t, 1}, \forall \dot{m}\_{\mathrm{v}, \mathrm{i}},\\) and \\(\forall \dot{m}\_{\mathrm{d}, \mathrm{i}}\\)  

- Mathematical formulation:   
   
 $$W=\dot{m}\_{\mathrm{t}, \mathrm{i}} \cdot\left\(h\_{\mathrm{t}, \mathrm{i}}-h\_{l}^{\mathrm{sat}}\right\)\right\)+\dot{m}\_{\mathrm{v}, \mathrm{i}} \cdot\left\(h\_{\mathrm{v}, \mathrm{i}}-h\_{l}^{\mathrm{sat}}\right\) + \dot{m}\_{\mathrm{d}, \mathrm{i}} \cdot \left\(h\_{\mathrm{d}, \mathrm{i}}-h\_{l}^{\mathrm{sat}}\right\)$$  

- Comments:   
   
 There are three sources of steam the turbine, the boiler outlet or turbine inlet valve, and the drain \(outlets of water heaters for instence\). The steam is assumed completely condensed.  


### Power exchanged between the hot and the cold fluids  


    
    

- Validity domain:   
   
 \\(W>0\\)  

- Mathematical formulation:   
   
 $$T^{\mathrm{sat}}-T\_{\mathrm{c}, \mathrm{o}}=\left\(T^{\mathrm{sat}}-T\_{\mathrm{c}, \mathrm{i}}\right\) \cdot e^{\frac{h\_{\mathrm{cond}} \cdot A \cdot\left\(T\_{\mathrm{c}, \mathrm{i}}-T\_{\mathrm{c}, \mathrm{o}}\right\)}{W}}$$  

- Comments:   
   
 The hot fluid is assumed to stay at saturation temperature between inlet and outlet of the condenser \(no desuperheating zone and no subcooled zone\).  


### Momentum balance equation \(cold fluid\)  


    
    

- Validity domain:   
   
 \\(\forall \dot{m}\_{\mathrm{c}}\\)  

- Mathematical formulation:   
   
 $$\Delta P\_{\mathrm{c}}=\Lambda\_{\mathrm{c}} \cdot \frac{\dot{m}\_{\mathrm{c}} \cdot\lvert \dot{m}\_{\mathrm{c}}\rvert }{\rho\_{\mathrm{c}}}$$   

- Comments:   
   
 Only friction pressure losses are taken into account.  

## References   
   
El Hefni, Baligh and Bouskela, Daniel (2019). [Modeling and Simulation of Thermal Power Plants with ThermoSysPro](https://link.springer.com/book/10.1007/978-3-030-05105-1), sect. 9.7.1. Springer Nature Switzerland AG.

Parameters

TypeNameDefaultDescription
Units.SI.AreaSCO10000Heat exchange surface
RealCPCE0.02Pressure loss coefficient for the water side (Pa.s²/(kg.m**3))
Units.SI.Heightz0.5Water level in the condenser
Units.SI.CoefficientOfHeatTransferKCO1Reference heat exchange coefficient
Units.SI.MassFlowRateQC0100Reference mass flow rate
Units.SI.TemperatureTref293Reference temperature
RealCOPR1Reference fouling coefficient
RealCOP1Actual fouling coefficient
Booleancontinuous_flow_reversalfalsetrue: continuous flow reversal - false: discontinuous flow reversal
Integermode_ee1IF97 region at the water inlet. 1:liquid - 2:steam - 4:saturation line - 0:automatic
Integermode_se1IF97 region at the water outlet. 1:liquid - 2:steam - 4:saturation line - 0:automatic
Integermode_ex0IF97 region at the extraction point. 1:liquid - 2:steam - 4:saturation line - 0:automatic

Connectors

TypeNameDefaultDescription
ThermoSysPro.WaterSteam.Connectors.FluidInletCeeCooling water inlet
ThermoSysPro.WaterSteam.Connectors.FluidOutletCseCooling water outlet
ThermoSysPro.WaterSteam.Connectors.FluidOutletCexExtraction water
ThermoSysPro.WaterSteam.Connectors.FluidInletCvtTurbine outlet
ThermoSysPro.WaterSteam.Connectors.FluidInletCepDrain inlet
ThermoSysPro.WaterSteam.Connectors.FluidInletCevVapor inlet

Components

TypeNameDefaultDescription
Units.SI.MassFlowRateQeeCooling water mass flow rate at the inlet
Units.SI.SpecificEnthalpyHeeCooling water specific anthalpy at the inlet
Units.SI.AbsolutePressurePeeCooling water pressure at the inlet
Units.SI.MassFlowRateQepDrain mass flow rate at the inlet
Units.SI.SpecificEnthalpyHepDrain specific enthalpy at the inlet
Units.SI.MassFlowRateQevVapor mass flow rate at the inlet
Units.SI.SpecificEnthalpyHevVapor specific enthalpy at the inlet
Units.SI.MassFlowRateQvtVapor mass flow rate leaving the turbine
Units.SI.SpecificEnthalpyHvtVapor specific enthalpy leaving the turbine
Units.SI.MassFlowRateQseCooling water mass flow rate at the outlet
Units.SI.SpecificEnthalpyHseCooling water specific enthalpy at the outlet
Units.SI.AbsolutePressurePseCooling water pressure at the outlet
Units.SI.MassFlowRateQexDrain mass flow rate at the outlet
Units.SI.SpecificEnthalpyHexDrain specific enthalpy at the outlet
Units.SI.AbsolutePressurePexDrain pressure at the outlet
Units.SI.SpecificEnthalpyHsateWater specific enthalpy at the saturation point
Units.SI.AbsolutePressurePcondVapor pressure inside the condenser
Units.SI.TemperatureTsatWater temperature at the saturation point
Units.SI.TemperatureTeeCooling water temperature at the inlet
Units.SI.TemperatureTseCooling water temperature at the outlet
Units.SI.Densityrho_eeCooling water density at the inlet
Units.SI.Densityrho_exWater density at the extraction point
Units.SI.CoefficientOfHeatTransferKT1First reference value for the exchange coefficient
Units.SI.CoefficientOfHeatTransferKT2Second reference value for the exchange coefficient
Units.SI.CoefficientOfHeatTransferXKCOHeat transfer coefficient
Units.SI.SpecificEnthalpyHmvFluid input average specific enthalpy
Units.SI.SpecificEnthalpyHmlExtraction water average specific enthalpy
Units.SI.PowerWHeat power released to the cold source
ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_phproexPropriétés de l'eau
ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_phproeePropriétés de l'eau
ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_phprosePropriétés de l'eau
ThermoSysPro.Properties.WaterSteam.Common.PropThermoSatlsat1
ThermoSysPro.Properties.WaterSteam.Common.PropThermoSatvsat1

Revisions

Author  

Baligh El Hefni