modelSteamGenerator_1SG

Individual steam generator
Diagram of SteamGenerator_1SG

Information

## Copyright © EDF 2002 - 2026   
## ThermoSysPro Version 4.2

Parameters

TypeNameDefaultDescription
AnnularHydraulicEquivalencedownComerHydraulicEquivalencefromAnnularVtoHydraulicEquivalence(V_DownComer, Leq/2, Dint_DownComer)
ThermoSysPro.Units.SI.DiameterDh_DownComerdownComerHydraulicEquivalence.DhHydraulic diameter of the annular downcomer
Realneq_DownComerdownComerHydraulicEquivalence.neqEquivalent number of circular pipes preserving the downcomer flow area
General › Geometry
IntegerNs5Number of segments in tubes and riser
Integern_tubes4085Number of pipes in parallel
ThermoSysPro.Units.SI.AreaS4669Heat exchange area
ThermoSysPro.Units.SI.Lengthe_tubes1.2e-3Pipe's wall thickness
ThermoSysPro.Units.SI.LengthDext_tubes22.0e-3Pipe's external Diameter
ThermoSysPro.Units.SI.LengthLeqS/(n_tubes*(Dext_tubes - 2*e_tubes)*Modelica.Constants.pi)Equivalent length for pipes and riser
RealhcCorr5.0Corrective term for the heat exchange coefficient (hc) inside all pipes - to tune correct Tcold_primary
General › Separator: from Riser volume to Dome
ThermoSysPro.Units.SI.VolumeV_sep7.0Volume of the separator
ThermoSysPro.Units.SI.LengthL_sep3.0Length of the separator
ThermoSysPro.Units.SI.LengthD_sepfromVtoDeq(V_sep, L_sep, 1)Equivalent diameter of the separator (considered one pipe)
General › Riser (Tube bundle in the secondary)
ThermoSysPro.Units.SI.VolumeV_Riser45.0Riser's volume
ThermoSysPro.Units.SI.LengthD_RiserfromVtoDeq(V_Riser, Leq/2, n_tubes)Equivalent diameter of the riser
RealK_riser10Pressure loss coefficient to tune correct recirculation rate
General › Dome
ThermoSysPro.Units.SI.VolumeV_Dome60.0Volume of the dome
ThermoSysPro.Units.SI.LengthL_Dome5.0Length of the dome
ThermoSysPro.Units.SI.LengthR_Domesqrt(V_Dome/(L_Dome*Modelica.Constants.pi))Radius of the dome
General › DownComer
ThermoSysPro.Units.SI.VolumeV_DownComer8.0Volume of the downcomer
ThermoSysPro.Units.SI.DiameterDint_DownComer4.0Inner diameter of the annular downcomer
General › MixARE
ThermoSysPro.Units.SI.VolumeV_MixARE12.0Volume where feedwater mixes with recirculation

Connectors

TypeNameDefaultDescription
ThermoSysPro.WaterSteam.Connectors.FluidOutletIfluidOutletI
ThermoSysPro.WaterSteam.Connectors.FluidInletIfluidInlet
ThermoSysPro.WaterSteam.Connectors.FluidInletIfluidInlet1
ThermoSysPro.WaterSteam.Connectors.FluidOutletIfluidOutletI1
ThermoSysPro.InstrumentationAndControl.Connectors.OutputRealoutputReal
Connectors.FluidOutletIfluidOutletI_purge

Components

TypeNameDefaultDescription
RealCirculationRateCirculation rate
ThermoSysPro.Units.SI.PowerW_GV_primaryPower from primary to SG
ThermoSysPro.Units.SI.PowerW_GV_secondaryPower from SG to secondary
DynamicOnePhaseFlowPipeUtubeHotLeg
DynamicOnePhaseFlowPipeUtubeColdLeg
Volumes.DynamicDrumDomeGV
ThermoSysPro.WaterSteam.PressureLosses.LumpedStraightPipeDPSeparateurCyclone
ThermoSysPro.WaterSteam.Volumes.VolumeCMixAlimDomeGV
ThermoSysPro.WaterSteam.PressureLosses.SingularPressureLossDPnulle_AlimDwnc
ThermoSysPro.WaterSteam.PressureLosses.SingularPressureLossDPnulle_DomeDwnc
ThermoSysPro.WaterSteam.Sensors.SensorPCapteurPAlim
PressureLosses.LumpedStraightPipeDownComerGVDownComerGV
Thermal.HeatTransfer.HeatExchangerWallheatExchangerWall
Thermal.HeatTransfer.HeatExchangerWallheatExchangerWall1
DynamicTwoPhaseFlowRiserRiserGV
Volumes.VolumeAvolumeA
Volumes.VolumeCvolumeA1
PressureLosses.SingularPressureLossDPnulle_Tcirc

Contents

NameDescription
fromVtoDeq
AnnularHydraulicEquivalence
fromAnnularVtoHydraulicEquivalence

Revisions

Author  

Baligh El Hefni