modelSteamExtractionSplitter
Splitter for steam extraction
Information
## Copyright © EDF 2002 - 2026 ## ThermoSysPro Version 4.2
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | alpha | 1 | Vapor mass fraction at the extraction/Vapor mass fraction at the inlet (0 <= alpha <= 1) |
| Integer | mode_e | 0 | IF97 region at the inlet. 1:liquid - 2:steam - 4:saturation line - 0:automatic |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Connectors.FluidInlet | Ce | ||
| Connectors.FluidOutlet | Cs | ||
| Connectors.FluidOutlet | Cex | Extraction outlet |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Real | x_ex | Vapor mass fraction at the extraction outlet | |
| Units.SI.AbsolutePressure | P | Fluid pressure | |
| Units.SI.SpecificEnthalpy | h | Fluid specific enthalpy | |
| ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_ph | proe | ||
| ThermoSysPro.Properties.WaterSteam.Common.PropThermoSat | lsat | ||
| ThermoSysPro.Properties.WaterSteam.Common.PropThermoSat | vsat |
Revisions
Authors Baligh El Hefni Daniel Bouskela