modelDegasifierVolume
Degasifier volume
Information
## Copyright © EDF 2002 - 2026 ## ThermoSysPro Version 4.2
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Units.SI.Volume | V | 160 | Degazifier volume |
| Units.SI.Volume | Vmax | 10 | Maximum volume of the liquid in the basins |
| Units.SI.SpecificHeatCapacity | Cpmetal | 460 | Metal specific heat |
| Units.SI.Mass | Mmetal | 10869 | Metal mass |
| Units.SI.AbsolutePressure | P0 | 1e5 | Initial fluid pressure (active if steady_state=false) |
| Units.SI.SpecificEnthalpy | h0 | 1e5 | Initial fluid specific enthalpy (active if steady_state=false) |
| Boolean | steady_state | true | true: start from steady state - false: start from (P0, h0) |
| Units.SI.Density | p_rho | 0 | If > 0, fixed fluid density |
| Integer | mode | 0 | IF97 region. 1:liquid - 2:steam - 4:saturation line - 0:automatic |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Connectors.FluidInlet | Ce1 | ||
| Connectors.FluidInlet | Ce2 | ||
| Connectors.FluidOutlet | Cs | ||
| Connectors.FluidInlet | Ce3 | ||
| Connectors.FluidInlet | Ce4 |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Units.SI.Power | W | Thermal power exchanged between the liquid and the basins | |
| Units.SI.Temperature | Tl | Saturation temperature of the liquid in the basins | |
| Real | x | Vapor mass fraction | |
| Units.SI.AbsolutePressure | P | Average fluid pressure | |
| Units.SI.SpecificEnthalpy | h | Fluid specific enthalpy | |
| Units.SI.Density | rho | Fluid density | |
| Units.SI.MassFlowRate | BQ | Right hand side of the mass balance equation | |
| Units.SI.Power | BH | Right hand side of the energy balance equation | |
| Real | rhols | ||
| ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_ph | pro | Propriétés de l'eau | |
| ThermoSysPro.Properties.WaterSteam.Common.PropThermoSat | lsat |
Revisions
Author Baligh El Hefni