modelPartialValve

Partial implementation of a physical valve

Extends from Interfaces.SISOFlow.

Information

Partial implementation of a physical valve. The interpretation of input u_in depends on invertInput as follows.

  • invertInput = false (non-inverted): 0=closed, 1=open;
  • invertInput = true (inverted): 0=open, 1=closed.

Parameters

TypeNameDefaultDescription
BooleaninvertInputfalse= true, if input u_in is inverted
Booleanenable_dp_rho_refEnables/ hides showing dp_ref and rho_ref
Realk_min0.03Remaining flow at actuation signal u = 0
Advanced › Reference values
SI.PressureDifferencedp_ref1e5Reference pressure difference
Medium.Densityrho_ref1000Reference density

Components

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealInputu_inValve control input signal []
RealuActuation input for flow calculation